CONDENSATE RETENTION AS A FUNCTION OF CONDENSATE FLOW RATE ON HORIZONTAL ENHANCED PIN-FIN TUBES
Yükleniyor...
Dosyalar
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Vinca Inst Nuclear Sci
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
The extent of condensate flooding as a function of condensate flow rate is measured on six horizontal pin-fin tubes (varying in circumferential pin-spacing) via simulated experimentation. Surface tension to density ratio is tested using three fluids namely water, ethylene glycol and R-141b. Results show that flooding was strongly effected by changing the condensate flow rate. An increase in flow rate caused a marginal decrease in flooding angle (an angle extracted from top of the test tube to the fully flooded flank). Similarly, circumferential pin-spacing also effected the retention angle and the effect goes on increasing by decreasing the surface tension to density ratio.
Açıklama
Anahtar Kelimeler
condensate, retention, pin-fin tube, flow rate, heat transfer