Comprehensive analysis of recurrence factors in cryoballoon AF ablation: integrating clinical, biomarkers, and echocardiographic parameters

dc.contributor.authorSoysal, Ali Ugur
dc.contributor.authorGulfidan, Asli
dc.contributor.authorRaimoglou, Damla
dc.contributor.authorAtıcı, Adem
dc.contributor.authorYalman, Hakan
dc.contributor.authorKucur, Mine
dc.contributor.authorOnder, Sukriye Ebru
dc.date.accessioned2025-05-10T19:55:02Z
dc.date.issued2024
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractAtrial fibrillation (AF) poses substantial challenges in cardiovascular diseases, impacting patient health and economic burdens. Understanding the mechanical effects of AF on the left atrium (LA) and assessing the influence of treatment modalities on LA functions are critical. This study aims to assess the efficacy of echocardiographic and biochemical parameters in predicting AF recurrence following second generation cryoballoon ablation (CB-2). Ninety-two patients with symptomatic AF, treated with CB-2 at Istanbul University-Cerrahpa & scedil;a, Faculty of Medicine, Department of Cardiology, were prospectively examined from January 2021 to July 2023. The study endeavors to develop a predictive model for AF recurrence, investigating the relationship between echocardiographic measurements and serum biomarkers with recurrence. The follow-up duration for echocardiographic assessments and biochemical analyses was systematically documented. The study revealed a significant enhancement in LA mechanical functions during echocardiographic follow-ups three months post-procedure. Specifically, LA strain parameters emerged as significant predictors of recurrence (LAsr: 95%CI 1.004-1.246, p = 0.047; LAsct: 95%CI 1.040-1.750, p = 0.024). Biochemical analyses demonstrated a correlation between elevated PRO-BNP levels and an increased risk of recurrence (95%CI 1.000-1.003, p = 0.012). Moreover, specific biomarkers such as MYBPHL, which demonstrated increased levels post-procedure, were deemed indicative of atrial damage, suggesting potential additional atrial substrate modification beyond PVI. Consequently, improvements in LA function post-cryoballoon ablation and biochemical markers have surfaced as potential indicators for predicting AF recurrence. This study elucidates the effectiveness of CB-2 in treating AF and its impact on LA functions. Notably, LA strain measurements and PRO-BNP levels have emerged as reliable indicators for predicting recurrence. Beyond clinical implications, our research establishes a foundation for a deeper understanding of the role of CB-2 in AF management and factors associated with recurrence.
dc.identifier.doi10.1007/s10554-024-03218-4
dc.identifier.endpage2281
dc.identifier.issn1569-5794
dc.identifier.issn1875-8312
dc.identifier.issue11
dc.identifier.pmid39147919
dc.identifier.scopusqualityQ2
dc.identifier.startpage2271
dc.identifier.urihttps://doi.org/10.1007/s10554-024-03218-4
dc.identifier.urihttps://hdl.handle.net/20.500.14730/13229
dc.identifier.volume40
dc.identifier.wosWOS:001292078000001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofInternational Journal of Cardiovascular Imaging
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectAtrial fibrillation
dc.subjectCryoballoon
dc.subjectEchocardiography
dc.subjectBiomarker
dc.subjectRecurrence
dc.titleComprehensive analysis of recurrence factors in cryoballoon AF ablation: integrating clinical, biomarkers, and echocardiographic parameters
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
13229.pdf
Boyut:
1.12 MB
Biçim:
Adobe Portable Document Format