Comparative Design Improvement of the Growing Rod for the Scoliosis Treatment Considering the Mechanical Complications

dc.contributor.authorDemir, Ugur
dc.contributor.authorAkgun, Gazi
dc.contributor.authorKocaoglu, Sitki
dc.contributor.authorOkay, Md. Erhan
dc.contributor.authorHeydar, Ahmed Majid
dc.contributor.authorAkdogan, Erhan
dc.contributor.authorYildirim, Alper
dc.date.accessioned2025-05-10T15:21:55Z
dc.date.issued2023
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractIn this study, the focus is on an implant used in the treatment of early-onset scoliosis called magnetically controlled growing rods (MCGR). The primary goal of the study is to address and propose solutions for the mechanical problems reported in the literature concerning MCGR. The problems of the MCGR are mainly due to excessive stress and mechanical bearing problems. Therefore, an MCGR removed from a patient is teardown and geometrically modeled. Then, eleven design parameters are determined on the MCGR for the mechanical problems experienced and these are evaluated by mechanical analysis over 14 control points. In this study, analysis processes are carried out with L12 orthogonal array for eleven design parameters and 2 levels using Taguchi's experimental design method (DoE). With the obtained data by analyzing the experiments in L12, the fitness functions depending on the design parameters are created for 14 control points. Since the problem is multi-objective, a non-dominated sorting genetic algorithm (NSGA II) and multi-objective particle swarm optimization (MOPSO) are used to minimize stress and displacement in existing mechanical problems using fitness functions. The obtained design models from NSGA II and MOPSO are analyzed and evaluated in comparison with the existing mechanical model obtained through pre-optimization teardown study of MCGR. © 2013 IEEE.
dc.identifier.doi10.1109/ACCESS.2023.3268147
dc.identifier.endpage40120
dc.identifier.issn2169-3536
dc.identifier.scopus2-s2.0-85153499884
dc.identifier.scopusqualityQ1
dc.identifier.startpage40107
dc.identifier.urihttps://doi.org/10.1109/ACCESS.2023.3268147
dc.identifier.urihttps://hdl.handle.net/20.500.14730/6230
dc.identifier.volume11
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.ispartofIEEE Access
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20250302
dc.subjectGrowing rod; mechanical complications; MOPSO; multi-objective optimization; NSGA II
dc.titleComparative Design Improvement of the Growing Rod for the Scoliosis Treatment Considering the Mechanical Complications