The effect of cooling Reciproc instruments prior to preparation on cyclic fatigue resistance at simulated body temperature
| dc.contributor.author | Arslan, Hakan | |
| dc.contributor.author | Doğanay Yıldız, Ezgi | |
| dc.contributor.author | Taş, Gizem | |
| dc.contributor.author | Bayındır, Oğuz | |
| dc.contributor.author | Topçuoğlu, Hüseyin Sinan | |
| dc.date.accessioned | 2025-05-10T14:05:51Z | |
| dc.date.issued | 2021 | |
| dc.department | İstanbul Medeniyet Üniversitesi | |
| dc.description.abstract | Purpose: This study aimed to examine the effect of cooling Reciproc endodontic files prior to preparation on their cyclic fatigue life at simulated body temperature. Methods: Sixty-four Reciproc R40 files were randomly split into 4 groups (n = 16), as follows: control, cooling at ?50°C, cooling at ?16°C, and cooling at ?80°C groups. The files were used in a simulated metal canal with a curvature of 90° and a radius of 3-mm. The metal block was submerged in a water tank adjusted to a temperature of 37°C. The time to file fracture and the length of the broken fragment were measured and recorded. The data were analyzed using a Kruskal–Wallis H test. Results: The time to fracture was significantly lower in the control group compared to the cooling groups (p< 0.05). No differences in the time to fracture (p> 0.05) were observed between the cooling groups, and all groups exhibited similar length of the fractured fragments (p> 0.05). Conclusion: Within the limitations of this study, it can be concluded that cooling Reciproc R40 files using different methods prior to preparation improves its cyclic fatigue resistance. | |
| dc.identifier.doi | 10.14744/TEJ.2021.79188 | |
| dc.identifier.endpage | 38 | |
| dc.identifier.issn | 2459-1726 | |
| dc.identifier.issue | 2 | |
| dc.identifier.startpage | 35 | |
| dc.identifier.trdizinid | 1169771 | |
| dc.identifier.uri | https://doi.org/10.14744/TEJ.2021.79188 | |
| dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/1169771 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14730/5441 | |
| dc.identifier.volume | 6 | |
| dc.indekslendigikaynak | TR-Dizin | |
| dc.language.iso | en | |
| dc.relation.ispartof | Turkish Endodontic Journal | |
| dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_TR-Dizin_20250302 | |
| dc.subject | Diş Hekimliği | |
| dc.subject | Mikrobiyoloji | |
| dc.title | The effect of cooling Reciproc instruments prior to preparation on cyclic fatigue resistance at simulated body temperature | |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1










