Application of solid Carbon dioxide as a novel hemostatic agent on a hepatectomy model in rats

dc.authorid0000-0002-8803-0874
dc.authorid0000-0002-4006-1583
dc.authorid0000-0002-1483-997X
dc.authorid0000-0002-4111-0885
dc.authorid0000-0003-0247-0332
dc.contributor.authorÖzemir, İbrahim Ali
dc.contributor.authorBilgic, Cagri
dc.contributor.authorAytac, Erman
dc.contributor.authorAslan, Sinan
dc.contributor.authorBayraktar, Barış
dc.contributor.authorIsbilen, Banu
dc.contributor.authorZemheri, Ebru
dc.date.accessioned2025-05-10T19:32:34Z
dc.date.issued2016
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBackground: Blood loss and the prolonged operative time for haemostasis is still a great problem after injury or during elective surgery of the liver. Various topical hemostatic agents were introduced to reduce the blood loss. The aim of this study is to evaluate the afficacy of solid carbon dioxide (SoCO(2)) as a hemostatic agent on hepatectomy model. Materials and Methods: Thirty-two Wistar albino female rats were included in this study. They were divided in four groups of 8 rats. Haematocrit levels were determined preoperatively. Non-anatomic hepatectomy was performed to the left lobe. Hemostasis was provided with gauze tampons in Group-1, with surgical sutures in Group-2 and with asistance of SoCO(2) in Group-3. Hemostasis time and blood loss were recorded. Serum haematocrit, liver function tests were determined postoperatively. SoCO(2) assisted hemostasis was provided and relaparotomy was performed after 7 days to determine the late effects of SoCO(2) in Group-4. Results: Blood loss in Group-1 and Group-2 were statistically significant higher than the Group-3 (119.1 +/- 22,4 mg; 80.6 +/- 18.9 mg; 36.3 +/- 11.1 mg, respectively) (p<0.01). Therewithal hemostasis time in Group-3 was statistically significant shorter than Group-1 and Group-2 (p<0.01). Serum ALT and AST values were increased in first three groups, but did not reveal significant difference between groups (p: 0.045 and p: 0.163). ALT and AST values were significantly decreased in Group-4 compared to other groups (p: 0.001 and p: 0.005, respectively). Conclusions: SoCO(2) assisted hemostasis provide bloodless surgical site, reduced blood loss and also shortened hemostasis time. Although further studies are requires, this study reveals that hepatectomies can be performed safer with SoCO(2) assistance.
dc.identifier.endpage866
dc.identifier.issn0970-938X
dc.identifier.issn0976-1683
dc.identifier.issue3
dc.identifier.scopus2-s2.0-84979074716
dc.identifier.scopusqualityN/A
dc.identifier.startpage860
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8309
dc.identifier.volume27
dc.identifier.wosWOS:000388456100048
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherAllied Acad
dc.relation.ispartofBiomedical Research-India
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectHemostasis
dc.subjectSolid carbon dioxide
dc.subjectHepatectomy
dc.titleApplication of solid Carbon dioxide as a novel hemostatic agent on a hepatectomy model in rats
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8309
Boyut:
603.16 KB
Biçim:
Adobe Portable Document Format