Evaluation of the 24-hour intraocular pressure and systemic blood pressure at the same time
| dc.authorid | 0000-0002-7745-0726 | |
| dc.contributor.author | Karadağ, Remzi | |
| dc.contributor.author | Koyun, E. | |
| dc.contributor.author | Ozsoy, I | |
| dc.contributor.author | Caliskan, M. | |
| dc.date.accessioned | 2025-05-10T19:50:18Z | |
| dc.date.issued | 2019 | |
| dc.department | İstanbul Medeniyet Üniversitesi | |
| dc.description.abstract | Purpose. To obtain simultaneous 24-hour contact lens voltage and systemic arterial blood pressure values with the Sensimed Triggerfish system and Hotter monitoring device. Methods. Ten primary open-angle glaucoma (POAG) and 8 pseudoexfoliation glaucoma (PXG) patients were included in the study. The Sensimed Triggerfish contact tens device was used to calculate the 24-hour IOP, and a Hotter sphygmomanometer device was used for simultaneous 24-hour blood pressure measurements. We define the 8:00 am-11:00 pm period measurements as diurnal values and the other measurements as nocturnal values. Results. The mean nocturnal systolic values (nocturnal SBP 120.5 +/- 3.4 for POAG and 122.8 +/- 5.3 mmHg for PXG) and diastolic BP (nocturnal DBP 70.2 +/- 1.9 for POAG and 68.1 +/- 1.2 mmHg for PXG) were lower than the diurnal (diurnal SBP 134.6 +/- 5.3 for POAG, 145.9 +/- 41.7 mmHg for PXG, diurnal DBP 79.4 +/- 5.8 for POAG and 78.6 +/- 5.1 mmHg for PXG) values, and these differences were statistically significant in both groups (P=0.001 in DBP in PXG and P<0.001 for other values). In addition, nocturnal CL voltage values (228.8 +/- 41.1 for POAG and 214.3 +/- 47.0 mVEq for PXG) were higher than the diurnal values (55.8 +/- 77.2 for POAG and 145.9 +/- 41.7 mVEq for PXG) in the POAG and PXG groups, and these were statistically significant as well (P < 0.001 for all). In the POAG and PXG groups, CL voltage had a statistically significant negative correlation with systolic (respectively, r: -0.248, P=0.001 and r: -0.272, P < 0.001) and diastolic (respectively, r: -0.115, P=0.036 and r: -0.160, P=0.028) BP values. Conclusion. We observed that CL voltage values rose during the nocturnal period, with a concomitant decrease in systolic and diastolic BP. (C) 2019 Elsevier Masson SAS. All rights reserved. | |
| dc.description.sponsorship | Istanbul Medeniyet University Foundation | |
| dc.description.sponsorship | the clinical study was supported by the Istanbul Medeniyet University Foundation. These funding organizations had no role in the design or conduct of this research. | |
| dc.identifier.doi | 10.1016/j.jfo.2019.03.007 | |
| dc.identifier.endpage | 745 | |
| dc.identifier.issn | 0181-5512 | |
| dc.identifier.issn | 1773-0597 | |
| dc.identifier.issue | 7 | |
| dc.identifier.pmid | 31104874 | |
| dc.identifier.scopus | 2-s2.0-85065617621 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 739 | |
| dc.identifier.uri | https://doi.org/10.1016/j.jfo.2019.03.007 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14730/12289 | |
| dc.identifier.volume | 42 | |
| dc.identifier.wos | WOS:000482551000025 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Masson Editeur | |
| dc.relation.ispartof | Journal Francais D Ophtalmologie | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20250302 | |
| dc.subject | 24-hour measurement | |
| dc.subject | Intraocular pressure | |
| dc.subject | Blood pressure | |
| dc.subject | Systolic blood pressure | |
| dc.subject | Diastolic blood pressure | |
| dc.subject | Triggerfish | |
| dc.title | Evaluation of the 24-hour intraocular pressure and systemic blood pressure at the same time | |
| dc.type | Article |