Medial malleolus fractures: A biomechanical comparison of tension band wiring fixation methods

dc.authorid0000-0002-6900-1226
dc.authorid0000-0003-0033-2454
dc.authorid0000-0002-4126-0306
dc.contributor.authorUygur, Esat
dc.contributor.authorPoyanli, Oguz
dc.contributor.authorMutlu, Ibrahim
dc.contributor.authorCelik, Talip
dc.contributor.authorAkpınar, Fuat
dc.date.accessioned2025-05-10T19:43:13Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBackground: This study compared the biomechanical properties of three different fixation methods of tension band wirings, used in the treatment of medial malleolus fractures. The first method used an innovative handmade bent pin for cerclage fixation. The second method used a U-shaped K-wire to attach the cerclage to the medial tibial cortex. These two novel fixation techniques were compared with the traditional tension band wiring technique which is fixated to the bone by a screw. Hypothesis: Novel fixation techniques of tension band wiring provide stable fixation. Material and methods: In this study 27 artificial bone models, which medial malleolus fractures were simulated on, were used. Using an electromechanical test device, the force required to pull out each implant was assessed and compared. Results: This study found that; while handmade bent pinning resulted averagely 840.25 N (range: 647-1066 + 118.72) and U-shaped K-wire fixation was 381.71 N (range: 176-651 + 150.2) pull out strength, traditional tension band wiring indicated 871.33 N (range: 549-1008 + 137.74) pull out strength. Discussion: Handmade bent pinning method provide similar results with traditional tension band wiring. Therefore, in suitable cases, it may be an acceptable alternative to traditional tension band wiring techniques when treating malleolar fractures. Although the outcomes of U-shaped K-wire fixation indicated lower than other two groups, the outcomes were comparable with the literature. So while performing tension band wiring, both handmade fixation systems may be used in certain cases. For Orthopaedic surgeons, it is better to know and think about these alternative handmade pinning systems created from simple K-wires during the surgery if needed. (C) 2018 Elsevier Masson SAS. All rights reserved.
dc.identifier.doi10.1016/j.otsr.2018.06.011
dc.identifier.endpage1263
dc.identifier.issn1877-0568
dc.identifier.issue8
dc.identifier.pmid30107278
dc.identifier.scopus2-s2.0-85052136960
dc.identifier.scopusqualityQ1
dc.identifier.startpage1259
dc.identifier.urihttps://doi.org/10.1016/j.otsr.2018.06.011
dc.identifier.urihttps://hdl.handle.net/20.500.14730/10537
dc.identifier.volume104
dc.identifier.wosWOS:000450918900023
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Masson, Corporation Office
dc.relation.ispartofOrthopaedics & Traumatology-Surgery & Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectMedial malleolus fractures
dc.subjectTension bad wiring
dc.subjectCerclage wiring
dc.titleMedial malleolus fractures: A biomechanical comparison of tension band wiring fixation methods
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10537.pdf
Boyut:
1.04 MB
Biçim:
Adobe Portable Document Format