Investigating the ablation efficiency of a 1940-nm thulium fibre laser for intraoral surgery

dc.authorid0000-0003-2764-567X
dc.authorid0000-0002-8624-6700
dc.authorid0000-0002-0773-9567
dc.contributor.authorGuney, M.
dc.contributor.authorTunc, B.
dc.contributor.authorGulsoy, M.
dc.date.accessioned2025-05-10T19:49:46Z
dc.date.issued2014
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractThe use of a laser in surgical procedures involving the soft tissues is advantageous due to its sterile and hemostatic nature. Several different lasers are in use for intraoral soft tissue surgery; however, small, efficient, and fibre-coupled lasers are favoured due to the tightly confined nature of the intraoral environment. This study proposes the use of a 1940-nm thulium fibre laser (Tm:fibre laser) for intraoral soft tissue procedures. Its thermal effects when used to make incisions were investigated. This laser was chosen due to its output wavelength, which is absorbed well by water in biological tissues. Lamb tongues were used in the experiments. The laser was coupled to a 600-pm silica fibre and incisions were made in contact mode with a continuous wave. The extent of ablation and coagulation produced were measured at three different speeds, powers, and numbers of passes. The thermal effects of laser power, movement speed, and number of passes on incision depth and ablation efficiency were determined. The Tm:fibre laser is a promising tool for intraoral surgery, with excellent absorption by tissue, good coagulative qualities, and easy to manipulate fibre output. Its use as an incisional tool with very little to no carbonization is shown in this study.
dc.description.sponsorshipTUBITAK Research Project [107E119]
dc.description.sponsorshipThis study was supported by TUBITAK Research Project 107E119.
dc.identifier.doi10.1016/j.ijom.2014.02.010
dc.identifier.endpage1021
dc.identifier.issn0901-5027
dc.identifier.issn1399-0020
dc.identifier.issue8
dc.identifier.pmid24656497
dc.identifier.scopus2-s2.0-84903887792
dc.identifier.scopusqualityQ1
dc.identifier.startpage1015
dc.identifier.urihttps://doi.org/10.1016/j.ijom.2014.02.010
dc.identifier.urihttps://hdl.handle.net/20.500.14730/12142
dc.identifier.volume43
dc.identifier.wosWOS:000339601900016
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherChurchill Livingstone
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectablation efficiency
dc.subjectthermal effects
dc.subjectthulium laser
dc.subjectintraoral surgery
dc.titleInvestigating the ablation efficiency of a 1940-nm thulium fibre laser for intraoral surgery
dc.typeArticle

Dosyalar