Effect of Repeated Sterilization by Different Methods on Strength of Carbon Fiber Rods Used in External Fixator Systems

dc.authorid0000-0002-9445-1552
dc.authorid0000-0002-4126-0306
dc.contributor.authorUnal, Omer Kays
dc.contributor.authorPoyanli, Oguz Sukru
dc.contributor.authorUnal, Ulku Sur
dc.contributor.authorMutlu, Hasan Hüseyin
dc.contributor.authorOzkut, Afsar Timucin
dc.contributor.authorEsenkaya, Irfan
dc.date.accessioned2025-05-10T19:38:48Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractObjectives: We aimed to study the effects of repeated sterilization, using different methods, on the carbon fiber rods of external fixator systems. Methods: We used a randomized set of 44 unused, unsterilized, and identical carbon fiber rods (11 x 200 mm), randomly assigned to 2 groups: unsterilized (4 rods) and sterilized (40 rods). The sterilized rods were divided into 2 groups, those sterilized in an autoclave and those sterilized using hydrogen peroxide. These were further divided into 5 subgroups based on the number of sterilization repetition to which the fibers were subjected (25, 50, 75, 100, and 200). A bending test was conducted to measure the maximum bending force, maximum deflection, flexural strength, maximum bending moment and bending rigidity. We also measured the surface roughness of the rods. Results: An increase in the number of sterilization repetition led to a decrease in maximum bending force, maximum bending moment, flexural strength, and bending rigidity, but increased maximum deflection and surface roughness (P < 0.01). The effect of the number of sterilization repetition was more prominent in the hydrogen peroxide group. Conclusions: This study revealed that the sterilization method and number of sterilization repetition influence the strength of the carbon fiber rods. Increasing the number of sterilization repetition degrades the strength and roughness of the rods.
dc.identifier.doi10.1097/BOT.0000000000001224
dc.identifier.endpage430
dc.identifier.issn0890-5339
dc.identifier.issn1531-2291
dc.identifier.issue8
dc.identifier.pmid29781943
dc.identifier.scopus2-s2.0-85056580863
dc.identifier.scopusqualityQ1
dc.identifier.startpage425
dc.identifier.urihttps://doi.org/10.1097/BOT.0000000000001224
dc.identifier.urihttps://hdl.handle.net/20.500.14730/9477
dc.identifier.volume32
dc.identifier.wosWOS:000451355100019
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Orthopaedic Trauma
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectcarbon fiber
dc.subjectsterilization
dc.subjecthydrogen peroxide
dc.subjectauto-clave
dc.subjectstrength
dc.titleEffect of Repeated Sterilization by Different Methods on Strength of Carbon Fiber Rods Used in External Fixator Systems
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
9477.pdf
Boyut:
1.1 MB
Biçim:
Adobe Portable Document Format