Comparison of CAD/CAM manufactured implant-supported crowns with different analyses

dc.authorid0000-0003-1194-0703
dc.authorid0000-0002-2865-372X
dc.contributor.authorYegin, Elif
dc.contributor.authorAtala, Mustafa Hayati
dc.date.accessioned2025-05-10T19:34:27Z
dc.date.issued2020
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBackground Present study compared the failure load of CAD/CAM-manufactured implant-supported crowns and the stress distribution on the prosthesis-implant-bone complex with different restoration techniques. Methods The materials were divided into four groups: group L-M: lithium disilicate ceramic (LDS, monolithic), group L-V: LDS ceramic (veneering), group ZL-M: zirconia-reinforced lithium silicate ceramic (ZLS, monolithic), group ZL-V: ZLS ceramic (veneering). Crown restorations were subjected to load-to-failure test (0.5 mm/min). Failure loads of each group were statistically analyzed (two-way ANOVA, post hoc Tukey HSD, alpha = 0.05). Finite element analysis (FEA) was used to compare the stress distribution of crown restorations. Results Group L-M had the highest failure load (2891.88 +/- 410.12 N) with a significant difference from other groups (p < 0.05). Although there was a significant difference between group ZL-M (1750.28 +/- 314.96 N) and ZL-V (2202.55 +/- 503.14 N), there was no significant difference from group L-V in both groups (2077.37 +/- 356.59 N) (p > 0.05). Conclusions The veneer application had opposite effects on ceramics, increased the failure load of ZLS and reduced it for LDS without a statistically significant difference. Both materials are suitable for implant-supported crowns. Different restorative materials did not influence the stress distribution, but monolithic restorations reduced the stress concentration on the implant and bone.
dc.description.sponsorshipAbant Izzet Baysal University Scientific Research Project Department in Bolu, Turkey [BAP-2016.06.06.1039]
dc.description.sponsorshipThe work was supported by Abant Izzet Baysal University Scientific Research Project Department in Bolu, Turkey (project no BAP-2016.06.06.1039).
dc.identifier.doi10.1186/s40729-020-00267-x
dc.identifier.issn2198-4034
dc.identifier.issue1
dc.identifier.pmid33106916
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1186/s40729-020-00267-x
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8519
dc.identifier.volume6
dc.identifier.wosWOS:000584385600001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer Japan Kk
dc.relation.ispartofInternational Journal of Implant Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectCAD
dc.subjectCAM
dc.subjectCeramics
dc.subjectDental implant
dc.subjectFinite element analysis
dc.subjectLoad-to-failure test
dc.titleComparison of CAD/CAM manufactured implant-supported crowns with different analyses
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8519.pdf
Boyut:
10.8 MB
Biçim:
Adobe Portable Document Format