Prenatal ultrasonographic findings of adhesion-membrane complex and its relation with obstetric history

dc.authorid0000-0002-6487-0860
dc.contributor.authorHocaoğlu, Meryem
dc.contributor.authorBatukan, Cem
dc.contributor.authorYuksel, Atil
dc.date.accessioned2025-05-10T19:45:28Z
dc.date.issued2021
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBackground: Intrauterine adhesions are usually detected incidentally during routine obstetric ultrasound and remain one of the reasons for concern for both clinicians and patients. Objective: Our objective was to document ultrasonographic findings of intrauterine adhesions detected in obstetric ultrasound and to investigate their correlation with obstetric history. Study Design: Detailed scans were performed in 685 singleton pregnancies at 16-24 weeks' gestation. Intrauterine adhesion was referred to as adhesion-membrane complex'' (AMC). Patients were divided into three groups: Group I consisted of patients with >= 1 therapeutic D&C associated with pregnancy but with neither vaginal delivery nor Cesarean section (CS). Group II consisted of patients with >= 1 CS but with neither vaginal delivery nor therapeutic D&C associated with pregnancy. Group III consisted of patients who were in their first pregnancy. Ultrasonographic properties of AMC and relationship between AMCs and obstetric history were investigated. Results: The incidence of AMC in Group I (n = 108), Group II (n = 189), and Group III (n = 388) was 11.1% (n = 12), 1.05% (n = 2) and 1.03% (n = 4), respectively. Positive history of D&C is associated with significantly increased risk of AMC (risk ratio:10.778; 95% confidence interval: 3.55-32.75). Also, previous history of CS is not associated with significantly increased risk of AMC (risk ratio: 1.026; 95% confidence interval: 0.19-5.55). The AMCs were located in the upper half in 7 (38,9%) and in the lower half of the uterus in 11 (61.1%) patients. The midpoint thickness of the AMC was between 0.75 and 5.10 mm (mean: 2.65 mm; SD +/- 1.2). The width of the AMC was between 2 and 52 mm (mean: 20.98; SD +/- 15.3), the heights of the AMCs were 5-60 mm (mean: 33.27 mm; SD +/- 17.0). In ten of the AMC positive patients (55.6%) a thick and bulbous free end and in eleven of them (61.1%) a Y image was detected. The mean gestational age at birth was 37.4 (SD +/- 3.3) weeks in 18 patients with AMC. There were no intrauterine fetal or perinatal deaths. None of the neonates had congenital abnormalities. Conclusions: Intrauterine adhesions detected in obstetric ultrasonography were redefined and renamed in a more comprehensible manner. Our results pointed out that while the positive history of D&C is associated with significantly increased risk of AMC, previous history of CS is not associated with significantly increased risk of AMC.
dc.identifier.doi10.1080/14767058.2020.1767573
dc.identifier.endpage104
dc.identifier.issn1476-7058
dc.identifier.issn1476-4954
dc.identifier.issue1
dc.identifier.pmid32429717
dc.identifier.scopusqualityQ1
dc.identifier.startpage99
dc.identifier.urihttps://doi.org/10.1080/14767058.2020.1767573
dc.identifier.urihttps://hdl.handle.net/20.500.14730/11278
dc.identifier.volume34
dc.identifier.wosWOS:000536389600001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofJournal of Maternal-Fetal & Neonatal Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectAmniotic sheet
dc.subjectintrauterine adhesions
dc.subjectadhesion-membrane complex
dc.subjectultrasound
dc.subjectpregnancy
dc.titlePrenatal ultrasonographic findings of adhesion-membrane complex and its relation with obstetric history
dc.typeArticle

Dosyalar