Precise placement of lag screws in operative treatment of trochanteric femoral fractures with a new guide system
| dc.authorid | 0000-0002-9445-1552 | |
| dc.authorid | 0000-0002-4126-0306 | |
| dc.contributor.author | Poyanli, Oguz S. | |
| dc.contributor.author | Soylemez, Salih | |
| dc.contributor.author | Ozkut, Afsar T. | |
| dc.contributor.author | Uygur, Esat | |
| dc.contributor.author | Kemah, Bahattin | |
| dc.contributor.author | Unal, Omer K. | |
| dc.date.accessioned | 2025-05-10T19:49:52Z | |
| dc.date.issued | 2015 | |
| dc.department | İstanbul Medeniyet Üniversitesi | |
| dc.description.abstract | Purpose: We assessed the accuracy of a new guide system that we developed to place lag screws in the proper position with the minimum number of attempts for operative treatment of trochanteric femoral fractures. Methods: A total of 55 consecutive trochanteric femoral fractures were treated with a cephalomedullary nail. The first 27 consecutive patients were treated with the standard operation (group A), while the new guide system was used in the last 28 consecutive patients (group B). The numbers of attempts to place K wires and the duration of surgery were noted. Accuracy of lag screw placement was evaluated by measuring the angle of deviation from the central axis of the femoral head. Results: Deviation values ranged from -11? to +15? for the 27 cases in group A, with a median absolute deviation of 8? +/- 6?. That in the 28 cases after the introduction of the new guide system (group B) ranged from -5? to +6?, with a median absolute deviation of 0.5? +/- 3? (P < 0.001). The total numbers of attempts to place lag screws and mean operation time decreased significantly after introduction of the new guide system (P < 0.001). Conclusions: With this new guide system, we are able to insert lag screws successfully in the optimal position even in most unstable fractures. The present study indicated that this new guide system and nail facilitate accurate placement of lag screws in the appropriate position with the minimum number of attempts. (C) 2015 Elsevier Ltd. All rights reserved. | |
| dc.identifier.doi | 10.1016/j.injury.2015.06.003 | |
| dc.identifier.endpage | 2195 | |
| dc.identifier.issn | 0020-1383 | |
| dc.identifier.issn | 1879-0267 | |
| dc.identifier.issue | 11 | |
| dc.identifier.pmid | 26117412 | |
| dc.identifier.scopus | 2-s2.0-84947037501 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 2190 | |
| dc.identifier.uri | https://doi.org/10.1016/j.injury.2015.06.003 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14730/12177 | |
| dc.identifier.volume | 46 | |
| dc.identifier.wos | WOS:000363901600017 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Sci Ltd | |
| dc.relation.ispartof | Injury-International Journal of The Care of The Injured | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20250302 | |
| dc.subject | Trochanteric femoral fractures | |
| dc.subject | Operative treatment | |
| dc.subject | Cephalomedullary nail | |
| dc.subject | Guide system | |
| dc.title | Precise placement of lag screws in operative treatment of trochanteric femoral fractures with a new guide system | |
| dc.type | Article |










