NEW GENERATION NAIL VS. PLATE IN THE TREATMENT OF UNSTABLE INTERTROCHANTERIC FEMORAL FRACTURE
| dc.authorid | 0000-0002-6494-6415 | |
| dc.contributor.author | Ozturan, Burak | |
| dc.contributor.author | Erinc, Samet | |
| dc.contributor.author | Oz, Tayyar Taylan | |
| dc.contributor.author | Özkan, Korhan | |
| dc.date.accessioned | 2025-05-10T19:35:17Z | |
| dc.date.issued | 2020 | |
| dc.department | İstanbul Medeniyet Üniversitesi | |
| dc.description.abstract | Objective: To compare antirotator proximal femoral nail (A-PFN) with antirotator dynamic hip screw (A-DHS). Methods: Fourteen proximal femur models with type 31/A2 fracture, according to the AO Foundation/Orthopaedic Trauma Association (AO/OTA) classification, were separated into two groups. Group 1 bones (n = 7) were fixed with A-PFN and Group 2 (n = 7) with A-DHS. A 5 mm/min axial load was applied to femur heads using a testing device. Results: Two of the seven models in the A-PFN group fractured at the proximal, and the other five at distal locking screw level. All models in the A-DHS group fractured at the tightened distal screw region. The median fracture load for the A-PFN group was 132.1 N (97.1-173.69 N range), and for the A-DHS group it was 81.7 N (75.15-89.12 N range). Conclusion: A-PFN-treated unstable intertrochanteric fractured models resisted to higher levels of axial load than the A-DHS-treated group, with statistically significant difference. However, clinical studies are required to support these results. | |
| dc.identifier.doi | 10.1590/1413-785220202806234631 | |
| dc.identifier.endpage | 315 | |
| dc.identifier.issn | 1413-7852 | |
| dc.identifier.issn | 1809-4406 | |
| dc.identifier.issue | 6 | |
| dc.identifier.pmid | 33328788 | |
| dc.identifier.scopus | 2-s2.0-85098590654 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 311 | |
| dc.identifier.uri | https://doi.org/10.1590/1413-785220202806234631 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14730/8784 | |
| dc.identifier.volume | 28 | |
| dc.identifier.wos | WOS:000596500100008 | |
| dc.identifier.wosquality | Q4 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Atha Comunicacao & Editora | |
| dc.relation.ispartof | Acta Ortopedica Brasileira | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WOS_20250302 | |
| dc.subject | Femoral fracture | |
| dc.subject | Fracture fixation | |
| dc.subject | Intramedullary and plate | |
| dc.title | NEW GENERATION NAIL VS. PLATE IN THE TREATMENT OF UNSTABLE INTERTROCHANTERIC FEMORAL FRACTURE | |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1










