Spectral resolution and speech perception after cochlear implantation using the round window versus cochleostomy technique

dc.authorid0000-0002-9092-7541
dc.authorid0000-0003-2944-6404
dc.contributor.authorDemir, B.
dc.contributor.authorYuksel, M.
dc.contributor.authorAtilgan, A.
dc.contributor.authorCiprut, A.
dc.contributor.authorBatman, C.
dc.date.accessioned2025-05-10T19:44:08Z
dc.date.issued2021
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractObjective To evaluate the spectral resolution achieved with a cochlear implant in users who were implanted using round window route electrode insertion versus a traditional cochleostomy technique. Methods Twenty-six patients were classified into two groups according to the surgical approach: one group (n = 13) underwent cochlear implantation via the round window technique and the other group (n = 13) underwent surgery via cochleostomy. Results A statistically significant difference was found in spectral ripple discrimination scores between the round window and cochleostomy groups. The round window group performed almost two times better than the cochleostomy group. Differences between Turkish matrix sentence test scores were not statistically significant. Conclusion The spectral ripple discrimination scores of patients who had undergone round window cochlear implant electrode insertion were superior to those of patients whose cochlear implants were inserted using a classical cochleostomy technique.
dc.identifier.doi10.1017/S0022215121001183
dc.identifier.endpage517
dc.identifier.issn0022-2151
dc.identifier.issn1748-5460
dc.identifier.issue6
dc.identifier.pmid33958008
dc.identifier.scopus2-s2.0-85105873018
dc.identifier.scopusqualityQ2
dc.identifier.startpage513
dc.identifier.urihttps://doi.org/10.1017/S0022215121001183
dc.identifier.urihttps://hdl.handle.net/20.500.14730/10841
dc.identifier.volume135
dc.identifier.wosWOS:000821657700007
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherCambridge Univ Press
dc.relation.ispartofJournal of Laryngology and Otology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectCochlear Implantation
dc.subjectRound Window
dc.subjectEar
dc.subjectSpectral Resolution
dc.subjectSpeech Perception
dc.subjectCochleostomy
dc.subjectSpectral Ripple Discrimination
dc.subjectCochlear Implants
dc.titleSpectral resolution and speech perception after cochlear implantation using the round window versus cochleostomy technique
dc.typeArticle

Dosyalar