The effect of a noise and light-reducing hat on the comfort and physiologic parameters of the preterm neonates

dc.contributor.authorAkarsu, Oezlem
dc.contributor.authorBalci, Serap
dc.date.accessioned2025-05-10T19:31:24Z
dc.date.issued2022
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractAim: This study was performed to evaluate the effect of hat that reduced noise and light on preterm neonatal comfort and physiologic parameters.Material and Methods: This randomized controlled experimental study was conducted with 60 preterm newborns aged 32-37 weeks in a neonatal intensive care unit. The hat, which was developed by the researchers, was designed with and without a visor. The newborns were randomly divided into two groups (hat with a visor = 30 newborns, hat without a visor = 30 newborns). Each group also formed its own control group because all parameters in each group were measured before wearing the hat. The comfort of the newborns was evaluated using the Premature Infant Comfort Scale. Heart rate, oxygen saturation, and respiratory rate were also measured.Results: It was found that there was a highly significant difference in terms of mean comfort score, heart rate, oxygen saturation, and respiratory rate of preterm newborns in the groups after wearing the hat compared with before the hat (p < 0.001). There was no significant difference between the groups in terms of comfort score, heart rate, oxygen saturation, and respiratory rate (p > 0.05).Discussion: The use of the noise and light-reducing hat positively affected the comfort and physiologic parameters of the preterm newborns.
dc.identifier.doi10.4328/ACAM.21219
dc.identifier.endpage1097
dc.identifier.issn2667-663X
dc.identifier.issue10
dc.identifier.scopusqualityN/A
dc.identifier.startpage1092
dc.identifier.urihttps://doi.org/10.4328/ACAM.21219
dc.identifier.urihttps://hdl.handle.net/20.500.14730/7931
dc.identifier.volume13
dc.identifier.wosWOS:000886534700008
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherBayrakol Medical Publisher
dc.relation.ispartofAnnals of Clinical and Analytical Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectComfort Hat
dc.subjectLight Noise
dc.subjectPreterm Newborn
dc.titleThe effect of a noise and light-reducing hat on the comfort and physiologic parameters of the preterm neonates
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
7931.pdf
Boyut:
273.36 KB
Biçim:
Adobe Portable Document Format