Evaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplasty

dc.contributor.authorKalcıoğlu, M. Tayyar
dc.contributor.authorUzun, Ismail Hakki
dc.contributor.authorYalcin, Muhammet
dc.contributor.authorMalkoc, Meral Arslan
dc.contributor.authorOgreten, Ayse Tuba
dc.contributor.authorHanege, Fatih Mehmet
dc.date.accessioned2025-05-10T19:31:41Z
dc.date.issued2015
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBackground: Glass ionomer cements (GIC) have been widely used in dentistry for many years. In recent years, GIC have also been used for ossiculoplasty. The bond strength of GIC used in ossiculoplasty and the way they may change over the years in the cementation area are being questioned. The bonding strength of the substance may be of importance for long-term outcomes. Aims: The aim of this study was to investigate the bond strength of different GIC on ossicles. Study Design: In vitro study. Methods: Twenty ossicles were obtained from patients who had undergone ear surgery. All specimens were randomly divided into four subgroups. All specimens were inserted into a specially designed apparatus for shear bond strength (SBS) testing. The tested materials [Aqua Meron (AM), Aqua Cem (AC), Ketac Cem (KC), and Otomimix CPB (OH)] were prepared and applied according to the manufacturer's instructions. The SBS was tested using a universal testing machine at a crosshead speed of 0.5 mm/min. Results: The mean SBSs were found to be 13.28 MPa, 23.43 MPa, 8.51MPa, and 1.78 MPa for AM, AC, KC, and OH, respectively. AC had the highest SBS, which was statistically significantly different from that of KC and OH (p<0.05). Both AM and KC had higher SBS than OH (p<0.05). Conclusion: The results obtained in this study by investigating the bone-bonding strength of cements widely used in ossiculoplasty demonstrate that some of these substances have a greater ability to bond to ossicles compared to others. Further clinical investigations are needed to test different parameters.
dc.identifier.doi10.5152/balkanmedj.2015.15829
dc.identifier.endpage29
dc.identifier.issn2146-3123
dc.identifier.issn2146-3131
dc.identifier.issue1
dc.identifier.pmid25759768
dc.identifier.scopus2-s2.0-84922838730
dc.identifier.scopusqualityQ1
dc.identifier.startpage23
dc.identifier.urihttps://doi.org/10.5152/balkanmedj.2015.15829
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8013
dc.identifier.volume32
dc.identifier.wosWOS:000351489300004
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherGalenos Publ House
dc.relation.ispartofBalkan Medical Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectBone cement
dc.subjectbond strength
dc.subjectossicles
dc.subjectossiculoplasty
dc.titleEvaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplasty
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8013.pdf
Boyut:
645.88 KB
Biçim:
Adobe Portable Document Format