Effect of an Additional Hydrophobic Adhesive Layer Application on the Clinical Performance of Class V Resin Composite Restorations: An 18-month Randomized Clinical Trial

dc.contributor.authorBerkman, M.
dc.contributor.authorTuncer, S.
dc.contributor.authorKarabay, F.
dc.contributor.authorDemirci, M.
dc.contributor.authorTekce, N.
dc.contributor.authorBaydemir, C.
dc.date.accessioned2025-05-10T19:35:55Z
dc.date.issued2024
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractObjectives: This study aimed to evaluate the 18-month clinical performance of two different one-step adhesives that were applied alone or with an additional hydrophobic adhesive layer to noncarious cervical lesions. Methods and Materials: One hundred sixty teeth in 31 patients were included in the study. Each patient received at least four restorations. A 2-hydroxyethylmethacrylate (HEMA)-containing one-step self-etch adhesive (Clearfil S3 Bond Plus, Kuraray Noritake, Noritake, Japan) and a HEMA-free universal adhesive (G-Premio Bond) were applied to noncarious cervical lesions with or without additional hydrophobic adhesive (Heliobond) randomly. Teeth were restored with a nanohybrid composite. Restorations were evaluated according to FDI criteria at baseline, 6-, 12-, and 18-month recalls. Data were analyzed with the Kruskal-Wallis and the Friedman analysis of variance (ANOVA) tests (alpha=0.05). Results: At 18 months, recall rates were 100%, and there was no significant difference between four different adhesive applications in terms of any criteria (p>0.05). The cumulative retention rates were 92.5%, 92.5%, 97.5%, and 100% for the restorations with one-step self-etch, onestep self-etch plus hydrophobic adhesive layer, a universal adhesive, and a universal adhesive plus hydrophobic adhesive layer, respectively. Conclusion: An additional hydrophobic adhesive layer was found to have no significant effect on the 18-month clinical performance of two different one-step adhesive systems with and without HEMA.
dc.description.sponsorshipResearch Fund of Istanbul University [31778]; Bilimsel Arastirma Projeleri Birimi, Istanbul Universitesi [31778]
dc.description.sponsorshipThe present work was supported by the Research Fund of Istanbul University. (Project No 31778) . Funding information: Bilimsel Arastirma Projeleri Birimi, Istanbul Universitesi, Grant/Award Number: 31778
dc.identifier.doi10.2341/23-024-C
dc.identifier.endpage654
dc.identifier.issn0361-7734
dc.identifier.issn1559-2863
dc.identifier.issue6
dc.identifier.pmid39407427
dc.identifier.scopus2-s2.0-85208688176
dc.identifier.scopusqualityQ2
dc.identifier.startpage642
dc.identifier.urihttps://doi.org/10.2341/23-024-C
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8983
dc.identifier.volume49
dc.identifier.wosWOS:001376786500001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherOperative Dentistry Inc
dc.relation.ispartofOperative Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectNoncarious Cervical Lesions
dc.subjectSelf-Etch Adhesives
dc.subjectUniversal Adhesives
dc.subjectBond Strength
dc.subjectEnamel
dc.subjectDentin
dc.subjectImmediate
dc.subjectBenefit
dc.titleEffect of an Additional Hydrophobic Adhesive Layer Application on the Clinical Performance of Class V Resin Composite Restorations: An 18-month Randomized Clinical Trial
dc.typeArticle

Dosyalar