Surgical treatment of displaced intraarticular calcaneus fractures using anatomical lateral frame plate

dc.contributor.authorEsenkaya, Irfan
dc.contributor.authorTurkmensoy, Fatih
dc.contributor.authorKemah, Bahattin
dc.contributor.authorPoyanli, Oguz Sukru
dc.date.accessioned2025-05-10T19:59:09Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBACKGROUND: The present study evaluated the results obtained from the anatomical lateral frame plate treatment of displaced intraarticular calcaneus fractures. METHODS: Overall, 14 displaced intraarticular fractures of 13 patients (3 females, 10 males; Mean age, 37.5 years) were included in the present study. Surgery was performed using widened lateral approach and supported by auto grafts following joint line reduction in all patients. They were then fixated by anatomical lateral frame plate. All the joints were stabilized by casting after the operation. All patients were prescribed controlled and full weight bearing at 6-8th and 12th weeks, respectively. RESULTS: Mean follow-up of patients was 28 months. The fractures were classified according to Sanders system. Clinical scoring of the patients was performed according to American Orthopaedic Foot and Ankle Society, Creighton-Nebraska, and Maryland systems. According to these systems, the mean scores of the patients were 83.7, 75.7, and 88.5 respectively. CONCLUSION: In the present study, we have defined the results of anatomical lateral frame plate treatment in patients with displaced intraarticular calcaneus fractures. We have obtained clinically and radiologically satisfactory results with the anatomical compatibility of plate to the lateral surface of the calcaneus.
dc.identifier.doi10.5505/tjtes.2017.62355
dc.identifier.endpage161
dc.identifier.issn1306-696X
dc.identifier.issue2
dc.identifier.pmid29569688
dc.identifier.scopus2-s2.0-85045057889
dc.identifier.scopusqualityQ3
dc.identifier.startpage156
dc.identifier.trdizinid266456
dc.identifier.urihttps://doi.org/10.5505/tjtes.2017.62355
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/266456
dc.identifier.urihttps://hdl.handle.net/20.500.14730/13763
dc.identifier.volume24
dc.identifier.wosWOS:000428238500011
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherTurkish Assoc Trauma Emergency Surgery
dc.relation.ispartofUlusal Travma Ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectCalcaneus fracture
dc.subjectintraarticular calcaneus fracture
dc.subjectlateral frame plate
dc.titleSurgical treatment of displaced intraarticular calcaneus fractures using anatomical lateral frame plate
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
13763.pdf
Boyut:
3.06 MB
Biçim:
Adobe Portable Document Format