Aphakia treatment with sutureless scleral fixation or retropupillary iris-claw intraocular lens implantation: visual acuity, anterior segment and keratometry outcomes

dc.authorid0000-0002-9795-8228
dc.authorid0000-0001-5571-3735
dc.contributor.authorToptan, Muesluem
dc.contributor.authorYilmaz, Omer Faruk
dc.contributor.authorOğuz, Halit
dc.date.accessioned2025-05-10T19:55:07Z
dc.date.issued2024
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractPurpose Evaluation of anterior segment parameters using the Scheimpflug corneal topography 1 year after surgery in patients who underwent sutureless scleral fixation intraocular lens (SFIOL) implantation using the modified Yamane technique and retropupillary iris-claw intraocular lens (RPIOL) implantation. Methods A total of 60 eyes from 57 patients who underwent sutureless SFIOL implantation and 57 eyes from 52 patients who underwent RPIOL implantation were included. Anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), anterior-posterior corneal astigmatism, and keratometric values were assessed using the Scheimpflug corneal topography (Pentacam HR, Germany). Results There was no statistically significant difference in postoperative UCVA and BCVA between the sutureless SFIOL and the RPIOL group (p = 0.236, p = 0.293, respectively). While there was no statistically significant difference in postoperative IOP between the two groups (p = 0.223), a statistically significant decrease in IOP was observed in both groups (p < 0.001). While there was no statistical difference between the sutureless SFIOL group and the RPIOL group in terms of spherical value (p = 0.441) and spherical equivalence (p = 0.237), there was a statistically significant difference in cylindrical value (p < 0.001). While there was a statistical difference in anterior astigmatism (p < 0.001), there was no statistical difference in posterior astigmatism (p = 0.405). There was no statistical difference in terms of ACV, ACD, and ACA between the sutureless SFIOL and the RPIOL group (p = 0.812, p = 0.770, p = 0.401, respectively). Conclusion In this study, although there was a statistical difference in cylindrical value and anterior corneal astigmatism between the sutureless SFIOL and RPIOL groups, vision was not affected. According to this study, sutureless SFIOL and RPIOL are two successful methods in terms of visual acuity, anterior segment, and keratometry outcomes in aphakic patients after phacoemulsification.
dc.description.sponsorshipScientific and Technological Research Council of Turkiye (TUBIdot;TAK)
dc.description.sponsorshipOpen access funding provided by the Scientific and Technological Research Council of Turkiye (TUB & Idot;TAK). The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.
dc.identifier.doi10.1007/s10792-024-03187-6
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.issue1
dc.identifier.pmid38914871
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1007/s10792-024-03187-6
dc.identifier.urihttps://hdl.handle.net/20.500.14730/13264
dc.identifier.volume44
dc.identifier.wosWOS:001253362800001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofInternational Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectAphakia
dc.subjectIris claw
dc.subjectSutureless scleral fixation
dc.subjectModified Yamane technique
dc.subjectAnterior segment structures
dc.subjectScheimpflug corneal topography
dc.titleAphakia treatment with sutureless scleral fixation or retropupillary iris-claw intraocular lens implantation: visual acuity, anterior segment and keratometry outcomes
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
13264.pdf
Boyut:
457.85 KB
Biçim:
Adobe Portable Document Format