Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples

dc.authorid0000-0002-9604-3341
dc.contributor.authorOzdemir, Mehmet
dc.contributor.authorAyan, Ugur
dc.contributor.authorSevik, Murat
dc.date.accessioned2025-05-10T19:44:29Z
dc.date.issued2020
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractAim The two most common human polyomaviruses are the BK (BKV) and JC viruses (JCV). Diseases associated with polyomavirus usually occur in cases of severe cellular immunosuppression. BKV and JCV can cause many diseases, especially if they are reactivated in an immunosuppressed host. The aim of this study is to compare and evaluate the results of real-time polymerase chain reaction (PCR) methods targeting the small and large T gene regions of the viral genome, considering polymorphisms occurring in the viral genome of BKV and JCV. Materials and Methods Urinary specimens of 82 patients were taken from immunosuppressed patient and sent to molecular microbiology laboratory of Meram Medical Faculty. The small t gene was investigated using a commercial kit (LightMix, Roche) by real-time PCR method. Large T gene was investigated by using the optimized in-house real-time PCR method. Sequence analysis was accepted as the standard method. Results BKV positivity was detected in 9 samples and JCV positivity in 61 samples by real-time PCR method specific to small t gene region; BKV positivity in 21 samples and JCV positivity in 67 samples were determined by real-time PCR method specific to the large T gene region. Statistically, there was a significant difference for BKV, but not significant difference for JCV detection between the two methods. Conclusion Different polymorphisms in the target gene regions were responsible for the different outcomes obtained from this study. With this sensitivity and specificity, in-house PCR method which we used is a candidate for routine diagnosis.
dc.identifier.doi10.1055/s-0040-1716603
dc.identifier.endpage83
dc.identifier.issn0974-2727
dc.identifier.issn0974-7826
dc.identifier.issue2
dc.identifier.pmid32905317
dc.identifier.scopusqualityN/A
dc.identifier.startpage79
dc.identifier.urihttps://doi.org/10.1055/s-0040-1716603
dc.identifier.urihttps://hdl.handle.net/20.500.14730/10954
dc.identifier.volume12
dc.identifier.wosWOS:000565252300001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherThieme Medical Publ Inc
dc.relation.ispartofJournal of Laboratory Physicians
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectBK virus
dc.subjectJC virus
dc.subjectreal-time PCR
dc.titleComparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10954.pdf
Boyut:
301.86 KB
Biçim:
Adobe Portable Document Format