Three-dimensional echocardiographic assessment of Chiari's network relationship with the left ventricular false tendon

dc.authorid0000-0003-1694-0606
dc.contributor.authorSumerkan, Mutlu Cagan
dc.contributor.authorCetin, Sukru
dc.contributor.authorHelvaci, Fusun Behramoglu
dc.contributor.authorYaslikaya, Sendag Satilmis
dc.contributor.authorKarabay, Umut
dc.contributor.authorHamit, Turgun
dc.contributor.authorGurdal, Ahmet
dc.date.accessioned2025-05-10T19:34:28Z
dc.date.issued2022
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBackground: Left ventricular false tendon (LVFT) is a fibromuscular band crossing the left ventricular cavity. And Chiari's network (CN) is a highly mobile, mesh-like, echogenic structure in right atrium. In this study, we aimed to evaluate the coexistence of LVFT in patients with CN. CN patients were examined with live/real-time three-dimensional transthoracic echocardiography (TTE) for visualization of LVFT. Results: This is a single-center prospective study of 49 patients with CN. In literature studies, the average ratios of LVFT were 22% in the normal population. In our study, an increased ratio of LVFT (n = 31, 63.3%) was found in CN patients evaluated with a three-dimensional TTE (63.3% versus 22%) (p = 0.01). The interatrial septal aneurysm was found in 31 (63.3%) patients with CN. And, the positive contrast echocardiography examination was determined in 22 (61.1%) patients with CN. Conclusions: Our study reveals that CN is associated with LVFT and is also associated with cardiac anomalies like an interatrial septal aneurysm, and atrial septal defect. And LVFT can be evaluated better with three-dimensional TTE than with traditional two-dimensional TTE. Patients with CN should be evaluated more carefully by three-dimensional echocardiography as they can be in synergy in terms of the cardiac pathologies they accompany.
dc.identifier.doi10.1186/s43044-022-00287-5
dc.identifier.issn1110-2608
dc.identifier.issn2090-911X
dc.identifier.issue1
dc.identifier.pmid35704119
dc.identifier.scopus2-s2.0-85131919948
dc.identifier.scopusqualityQ3
dc.identifier.urihttps://doi.org/10.1186/s43044-022-00287-5
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8528
dc.identifier.volume74
dc.identifier.wosWOS:000811741700001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofEgyptian Heart Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectAbnormalities
dc.subjectCardiovascular
dc.subjectChiari's network
dc.subjectThree-Dimensional echocardiography
dc.subjectFalse tendon
dc.titleThree-dimensional echocardiographic assessment of Chiari's network relationship with the left ventricular false tendon
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8528.pdf
Boyut:
1.25 MB
Biçim:
Adobe Portable Document Format