The utility of ADC measurement techniques for differentiation of low- and high-grade clear cell RCC

dc.authorid0000-0002-0848-3559
dc.authorid0000-0003-2726-2097
dc.contributor.authorAslan, Ahmet
dc.contributor.authorİnan, İbrahim
dc.contributor.authorAktan, Ahmet
dc.contributor.authorAyaz, Ercan
dc.contributor.authorAslan, Mine
dc.contributor.authorOzkanli, Sidika Seyma
dc.contributor.authorYıldırım, Asıf
dc.date.accessioned2025-05-10T19:31:38Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractPurpose: To evaluate the diffusion properties of clear cell renal cell carcinoma (ccRCC) on magnetic resonance imaging (MRI) concerning their Fuhrman nuclear grades and sizes, and to compare the diagnostic performance of two ROI placement techniques for apparent diffusion coefficient (ADC) measurement (entire mass vs. only the darkest region of the mass). Material and methods: Fifty-one ccRCC were enrolled in the study and grouped into low-grade ccRCC (Fuhrman grade 1 and 2, n = 37) and high-grade ccRCC (Fuhrman grade 3 and 4, n = 14). Selective ADC (Sel-ADC) measurement was performed by placing a circular ROI that included the darkest region of the tumour on ADC map images. Extensive ADC (Ext-ADC) measurement was performed by drawing an ROI that covered the entire tumour. Results: The Sel-ADC value was lower in high-grade ccRCC (p = 0.019), whereas the Ext-ADC value did not show a statistically significant difference (p = 0.42). Sel-ADC value of a <= 1.405 mm(2)/s has a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy value of 78.6, 72.2, 73.87, 77.13, and 75.4, respectively, to differentiate high-grade from low-grade ccRCC. The size and Fuhrman grade of the ccRCC were inversely correlated with the Sel-ADC value; however, the correlations were weak (r = -0.322, p = 0.021 and r = -0.376, p = 0.006, respectively). There was no difference between ADC values of small (<= 4 cm) and large (> 4 cm) ccRCCs. Conclusions: The ADC value of the darkest region in solid part of the ccRCC may play a role in predicting the nuclear grade of ccRCC.
dc.identifier.doi10.5114/pjr.2018.80207
dc.identifier.endpageE451
dc.identifier.issn0137-7183
dc.identifier.issn1899-0967
dc.identifier.pmid30655922
dc.identifier.scopus2-s2.0-85061107193
dc.identifier.scopusqualityQ3
dc.identifier.startpageE446
dc.identifier.urihttps://doi.org/10.5114/pjr.2018.80207
dc.identifier.urihttps://hdl.handle.net/20.500.14730/7988
dc.identifier.volume83
dc.identifier.wosWOS:000454223700001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherInt Scientific Information Inc
dc.relation.ispartofPolish Journal of Radiology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectmagnetic resonance imaging
dc.subjectapparent diffusion coefficient
dc.subjectclear cell renal cell carcinoma
dc.subjectdiffusion-weighted imaging
dc.subjectFuhrman grading system
dc.titleThe utility of ADC measurement techniques for differentiation of low- and high-grade clear cell RCC
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
7988.pdf
Boyut:
745.66 KB
Biçim:
Adobe Portable Document Format