Femtosecond lenticule extraction for correction of myopia: a 6 month follow-up study

dc.authorid0000-0001-8197-2458
dc.authorid0000-0001-5435-075X
dc.contributor.authorDemirok, Ahmet
dc.contributor.authorAğca, Alper
dc.contributor.authorÖzgürhan, Engin Bilge
dc.contributor.authorBozkurt, Ercument
dc.contributor.authorCelik, Ugur
dc.contributor.authorDemircan, Ali
dc.contributor.authorGuleryuz, Nimet Burcu
dc.date.accessioned2025-05-10T19:35:38Z
dc.date.issued2013
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractAims: To report our initial experience with femtosecond lenticule extraction ( FLEX) compared with femtosecond laser-assisted in situ keratomileusis (LASIK). Settings and design: This was a prospective pilot study carried out at the Refractive Surgery Department of the Beyoglu Eye Training and Research Hospital, Istanbul, Turkey. Materials and methods: Surgery was performed on both eyes of 14 consecutive patients with myopia or myopic astigmatism. Patients underwent FLEX in one eye and femtosecond LASIK (FemtoLASIK) in the other eye. The primary outcome was based on uncorrected distance visual acuity, corrected distance visual acuity, and spherical equivalent of the subjective manifest refraction, at 1 week, 1 onth, and 6 Mnths postsurgery. Statistical analyses were performed using PAWS Statistics 18. Unpaired Student's t-test was used to compare the groups. Results: During the last follow-up visit (6months postsurgery), the mean spherical was -0.37 +/- 0.60 diopters (D) (range - 1.00 to 0.50) (P<.001) and - 0.25 +/- 0.41 D (range - 0.88 to 0.12 D) ( 0.001) in the FLEX and FemtoLASIK eyes, respectively. The spherical was within 0.50 D of the intended correction in ten (72%) of the FLEX eyes and 12 ( 86%) of the FemtoLASIK eyes (P>.05). No complications occurred during surgery or the postoperative period. Conclusion: FLEX is a safe, effective, and predictable procedure for surgical correction of myopia. Refractive results were stabilized within the first postoperative week, and visual acuities were stabilized within the first month, comparable to FemtoLASIK.
dc.identifier.doi10.2147/OPTH.S45225
dc.identifier.endpage1047
dc.identifier.issn1177-5483
dc.identifier.pmid23766626
dc.identifier.scopusqualityQ2
dc.identifier.startpage1041
dc.identifier.urihttps://doi.org/10.2147/OPTH.S45225
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8902
dc.identifier.volume7
dc.identifier.wosWOS:000215966300163
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherDove Medical Press Ltd
dc.relation.ispartofClinical Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectFLEX
dc.subjectfemtosecond laser-assisted in situ keratomileusis
dc.titleFemtosecond lenticule extraction for correction of myopia: a 6 month follow-up study
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8902.pdf
Boyut:
569.39 KB
Biçim:
Adobe Portable Document Format