dc.description.abstractPurpose:To assess changes in anterior-chamber depth (ACD) and angle width after neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy pseudophakia in eyes with pseudoexfoliation (PEX).Methods:This prospective and interventional case series study included 25 pseudophakic eyes of 25 patients with PEX and 26 pseudophakic eyes of 26 patients without PEX scheduled for Nd:YAG laser capsulotomy in a single institution. Anterior-chamber depth and angle width were measured with anterior segment optical coherence tomography before and three days after Nd:YAG laser capsulotomy. Preoperative and postoperative measurements of ACD and angle width included the angle opening distance (AOD), measured as the perpendicular distance from the trabecular meshwork at 500 and 750 mm anterior to the scleral spur to the anterior iris surface (AOD500 and AOD750, respectively) and anterior-chamber angle (ACA) in the nasal and temporal quadrants. Main outcome measures were the changes in ACD and angle width parameters.Results:The mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.670.12 mm, 0.63 +/- 0.05 mm and 0.65 +/- 0.05 mm, 0.67 +/- 0.06 mm and 0.77 +/- 0.04 mm, 35.25 +/- 1.69 degrees and 35.37 +/- 1.68 degrees in eyes with PEX and 3.73 +/- 0.11 mm, 0.6 +/- 0.05 mm and 0.63 +/- 0.05 mm, 0.66 +/- 0.06 mm and 0.74 +/- 0.06 mm, 34.24 +/- 1.6 degrees and 34.6 +/- 1.47 degrees in control eyes, respectively (P>0.05 for all). After Nd:YAG laser capsulotomy, mean ACD, AOD500, AOD750, and ACA (nasal and temporal) measurements were 3.76 +/- 0.09 mm, 0.73 +/- 0.05 mm and 0.76 +/- 0.05 mm, 0.75 +/- 0.06 mm and 0.87 +/- 0.04 mm, 36.82 +/- 1.46 degrees and 35.06 +/- 1.52 degrees in eyes with PEX and 3.77 +/- 0.1 mm, 0.68 +/- 0.06 mm and 0.72 +/- 0.06 mm, 0.72 +/- 0.05 mm and 0.84 +/- 0.06 mm, 34.95 +/- 1.4 degrees and 35.79 +/- 1.36 degrees in control eyes, respectively (P=0.811, P=0.019, P=0.021, P=0.109, P=0.126, P=0.001, and P=0.01, respectively).Conclusions:The depth and width of the anterior chamber in eyes with PEX and in control eyes increased significantly after Nd:YAG laser capsulotomy. The change in the width of the anterior chamber in eyes PEX was statistically significant comparing control eyes.
dc.identifier.doi10.1097/ICL.0000000000000185
dc.identifier.endpage321
dc.identifier.issn1542-2321
dc.identifier.issn1542-233X
dc.identifier.issue5
dc.identifier.pmid26322919
dc.identifier.scopusqualityQ1
dc.identifier.startpage318
dc.identifier.urihttps://doi.org/10.1097/ICL.0000000000000185
dc.identifier.urihttps://hdl.handle.net/20.500.14730/9497
dc.identifier.volume42
dc.identifier.wosWOS:000384001400010
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofEye & Contact Lens-Science and Clinical Practice
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectNd:YAG laser capsulotomy
dc.subjectPosterior capsule opacification
dc.subjectPseudoexfoliation
dc.subjectAnterior-chamber depth
dc.subjectAnterior-chamber angle width
dc.subjectAnterior segment optical coherence tomography
dc.titleAnterior Segment Optical Coherence Tomography Assessment After Laser Capsulotomy in Pseudophakic Eyes With Pseudoexfoliation
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
9497.pdf
Boyut:
114.54 KB
Biçim:
Adobe Portable Document Format