Ex-PRESS implantation for different types of glaucoma

dc.contributor.authorAltinel, Meltem Guzin
dc.contributor.authorKanra, Ayse Yagmur
dc.contributor.authorKaradağ, Remzi
dc.contributor.authorBayramlar, Hüseyin
dc.date.accessioned2025-05-10T19:35:22Z
dc.date.issued2019
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractAIM: To evaluate the clinical results, efficacy and safety of Ex-PRESS P200 glaucoma shunt implant in different types of medically uncontrolled glaucoma. METHODS: The study included 31 eyes of 31 patients that were unresponsive to medical antiglaucomatous therapy in whom Ex-PRESS P200 glaucoma shunt implantation was performed. The demographic characteristics of the patients, type of glaucoma, complete ocular examination results, number of antiglaucomatous drugs before and after surgery, early and late complications of surgery, additional surgical and nonsurgical medical interventions, and success rates were investigated from the patients' files, retrospectively. RESULTS: The mean postoperative follow-up time was 16.4 +/- 7.5mo. The preoperative mean corrected intraocular pressure (IOP) was 28.7 +/- 10.3 mm Hg and postoperative mean corrected IOP was 15.3 +/- 5.2 mm Hg (P<0.05) at the last visit. The mean IOP reduction was 39.9% when the preoperative and postoperative values of the last visits were compared. The average number of antiglaucomatous drug use decreased from 3.9 +/- 0.3 to 1.7 +/- 1.7 postoperatively (P<0.05). The use of antiglaucomatous medications at the last visit was more than in other studies in the literature. The most common complication was conjunctival leakage, which was seen in 7 patients. Other early complications were iris touch, intravitreal hemorrhage, hyphema, choroidal effusion, early transient hypotonia and corneal edema. One of the late complications was endophthalmitis which was seen in one case 6mo after the operation, and the other late complication was opacification of the cornea in one patient. Twelve additional surgical operations associated to Ex-PRESS surgery and 3 bleb needling have done. At the last visit, the complete success rate was 32.3% and the qualified success rate was 77.5% in all patients. CONCLUSION: Ex-PRESS P200 glaucoma shunt implantation may be an effective procedure for medically uncontrolled glaucoma with significantly lower use of antiglaucomatous medications.
dc.identifier.doi10.18240/ijo.2019.08.09
dc.identifier.endpage1297
dc.identifier.issn2222-3959
dc.identifier.issn2227-4898
dc.identifier.issue8
dc.identifier.pmid31456919
dc.identifier.scopus2-s2.0-85074066444
dc.identifier.scopusqualityQ2
dc.identifier.startpage1290
dc.identifier.urihttps://doi.org/10.18240/ijo.2019.08.09
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8842
dc.identifier.volume12
dc.identifier.wosWOS:000481721800009
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherIjo Press
dc.relation.ispartofInternational Journal of Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectglaucoma
dc.subjectEx-PRESS implant
dc.subjectglaucoma surgery
dc.titleEx-PRESS implantation for different types of glaucoma
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8842.pdf
Boyut:
846.73 KB
Biçim:
Adobe Portable Document Format