Effects of etidronate, NaOCl, EDTA irrigation solutions and their combinations on cyclic fatigue resistance of nickel-titanium single-file rotary and reciprocating instruments at body temperature

dc.authorid0000-0003-3299-3361
dc.contributor.authorErik, Cevat Emre
dc.contributor.authorOzyurek, Taha
dc.date.accessioned2025-05-10T19:54:59Z
dc.date.issued2019
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractThe aim of the present study was to compare the effect of etidronic acid (HEBP), NaOCl, and EDTA solutions and their combinations on cyclic fatigue resistance of NiTi RPC Blue (RPC Blue), HyFlex EDM (HEDM), and WaveOne Gold (WOG) instruments having different metallurgic characteristics at the body temperature (37 degrees C). 100 WOG, 100 RPC Blue, and 100 HEDM NiTi files were randomly divided into 5 groups and immersed in the following solutions: group 1, distilled water; group 2, 6% NaOCl; group 3, 17% EDTA; group 4, 18% HEBP; group 5, 6% NaOCl and 18% HEBP. Then the instruments were rotated in an artificial canal until fracture occurred and the number of cycles to fracture was calculated. A univariate analysis of variance and post hoc Tukey tests were then performed for comparisons using SPSS 21.0 software with the significance level set at P<.05. In all the conditions, there was no difference between the cyclic fatigue resistance of WOG and RPC Blue files (P>.05). In the intragroup comparison, WOG, RPC Blue, and HEDM files showed significantly low cyclic fatigue resistance in group 5 compared to other groups (P<.05). Among the groups, there was no statistically significant difference in the fracture lengths (P>.05). EDTA, NaOCl and HEBP solutions did not affect the cyclic fatigue resistance of the tested files when used without combination. However, the combination of NaOCl and HEBP solutions significantly reduced the cyclic fatigue resistance of the tested files.
dc.identifier.doi10.1007/s10266-018-0388-8
dc.identifier.endpage195
dc.identifier.issn1618-1247
dc.identifier.issn1618-1255
dc.identifier.issue2
dc.identifier.pmid30209682
dc.identifier.scopus2-s2.0-85053416302
dc.identifier.scopusqualityQ1
dc.identifier.startpage190
dc.identifier.urihttps://doi.org/10.1007/s10266-018-0388-8
dc.identifier.urihttps://hdl.handle.net/20.500.14730/13203
dc.identifier.volume107
dc.identifier.wosWOS:000462994000009
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofOdontology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectCyclic fatigue resistance
dc.subjectIrrigating solution
dc.subjectReciproc Blue
dc.subjectHyFlex EDM
dc.subjectWaveOne Gold
dc.titleEffects of etidronate, NaOCl, EDTA irrigation solutions and their combinations on cyclic fatigue resistance of nickel-titanium single-file rotary and reciprocating instruments at body temperature
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
13203
Boyut:
1.24 MB
Biçim:
Adobe Portable Document Format