Biomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails

dc.authorid0000-0002-7402-756X
dc.authorid0000-0002-7038-4017
dc.contributor.authorErden, Tunay
dc.contributor.authorKapicioglu, Mehmet
dc.contributor.authorDemirtas, Abdullah
dc.contributor.authorBilsel, Kerem
dc.contributor.authorAkpınar, Fuat
dc.contributor.authorKuduz, Hacer
dc.date.accessioned2025-05-10T19:59:26Z
dc.date.issued2019
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractObjective: The aim of this study was to compare the biomechanical resistance to rotational and axial forces of a conventional locking nail with a newly designed intramedullary humeral nail developed for humeral shaft fractures with a secure locking mechanism through the distal part of the nail. Methods: InSafeLOCK humeral nail system (group 1, TST, Istanbul, Turkey) and Expert humeral nail system (group 2, DePuy Synthes, Bettlach, Switzerland) of the same size (9 x 300 mm) were examined. In total, 24 fourth-generation humerus sawbones were used in the experiment. Osteotomy was performed at the humerus shaft, and a defect was created by removing 1 cm of bone. After pre-loading 5000 cycles at a frequency of 2 Hz and a force of 50-250 N for axial loading and 5000 torsion torques between 0.5 Nm and 6.5 Nm at a 2 Hz frequency for torsional loading, the failure load values of each load were recorded. Distal interlocking was performed with an endopin in group 1, while a double cortex screw was used in group 2. Results: All samples successfully passed the cyclic loading. The initial and final stiffness values were similar between the groups after axial loading (p = 0.873 and p = 0.522, respectively). The mean axial failure load values in groups 1 and 2 were 2627 +/- 164 N and 7141 +/- 1491 N, respectively. A significant difference was found in the axial failure load values (p = 0.004). Significant differences were observed between the initial and final torsional stiffness between the two groups (p = 0.004 and p = 0.004, respectively). No significant difference was found in the failure load values after torsional loading (11791 +/- 2055 N.mm and 16997 +/- 5440 N.mm) (p = 0.055). Conclusion: These results provide a biomechanical demonstration of the adequate stability of both nails after axial and rotational loading. The reliability of the newly developed InSafeLOCK humeral nail system, which does not require fluoroscopic control and an additional incision for distal locking, supports its use in the clinic. (C) 2019 Turkish Association of Orthopaedics and Traumatology. Publishing services by Elsevier B.V.
dc.identifier.doi10.1016/j.aott.2019.08.003
dc.identifier.endpage496
dc.identifier.issn1017-995X
dc.identifier.issue6
dc.identifier.pmid31562026
dc.identifier.scopus2-s2.0-85072542385
dc.identifier.scopusqualityQ2
dc.identifier.startpage490
dc.identifier.trdizinid331744
dc.identifier.urihttps://doi.org/10.1016/j.aott.2019.08.003
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/331744
dc.identifier.urihttps://hdl.handle.net/20.500.14730/13849
dc.identifier.volume53
dc.identifier.wosWOS:000506165700017
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherTurkish Assoc Orthopaedics Traumatology
dc.relation.ispartofActa Orthopaedica Et Traumatologica Turcica
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectHumeral
dc.subjectBiomechanics
dc.subjectIntramedullary nail
dc.subjectFracture
dc.subjectDistal locking
dc.subjectAxial and torsional stiffness
dc.titleBiomechanical comparison of humeral nails with different distal locking mechanisms: Insafelock nails versus conventional locking nails
dc.typeArticle