A New Technique for Radiopacity Evaluation of Resin Cements

dc.contributor.authorYeğin, Elif
dc.contributor.authorHayati Atala, Mustafa
dc.contributor.authorFatih Kocaer, Ahmet
dc.date.accessioned2025-05-10T15:22:03Z
dc.date.issued2021
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractIntroduction: The aim of the present study was the comparison of radiopacity of different resin cement types using direct digital radiography by calibrating the calculations on the radiogram according to the dead pixel value on the phosphor plate for the first time in literature. Methods: The radiopacities of currently used ten different resin cements(G-CEM, I-CEM, Choice 2, Duo Link, TheraCem, eCEMENT DC, MaxCem Elite Chroma, BisCem, NX3, and Maxcem Elite), enamel and dentin were compared with the densitometer. The digital radiographs were acquired and Image J software was used to convert the images into numerical data for analysis. After the dead pixel calibration, the equivalent aluminum thickness value of each sample was calculated by the correlation analysis method. Results: According to test results, although there was no significant difference between G-CEM and I-CEM, all the materials, enamel and dentin had a significant difference from each other. MaxCem Elite had the highest radiopacity while G-CEM had the lowest. Conclusions: eCEMENT DC, MaxCem Elite Chroma, BisCem, NX3, and Maxcem Elite had higher radiopacity than dentin. Those with lower radiopacity than dentin (G-CEM, I-CEM, Choice 2, Duo Link, and TheraCem) should be carefully used in both subgingival located or radiolucent restorations and implant-supported prostheses. Dead pixel calibration enables materials to be evaluated more accurately and this method will also make it possible for the first time in literature to compare the same samples with each other on different phosphor plates. © 2021, Mashhad University of Medical Sciences. All rights reserved.
dc.identifier.doi10.22038/JDMT.2021.59788.1468
dc.identifier.endpage231
dc.identifier.issn2322-4150
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85186442374
dc.identifier.scopusqualityQ4
dc.identifier.startpage224
dc.identifier.urihttps://doi.org/10.22038/JDMT.2021.59788.1468
dc.identifier.urihttps://hdl.handle.net/20.500.14730/6289
dc.identifier.volume10
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherMashhad University of Medical Sciences
dc.relation.ispartofJournal of Dental Materials and Techniques
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_Scopus_20250302
dc.subjectCalibration; Dead Pixel; Radiopacity; Resin Cement
dc.titleA New Technique for Radiopacity Evaluation of Resin Cements
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
6289
Boyut:
538.86 KB
Biçim:
Adobe Portable Document Format