Improving Accuracy of Double Reading in Chest X-Ray Images by Using Eye-gaze Metrics

dc.contributor.authorVural, Ulas
dc.contributor.authorSarisoy, H. Tahsin
dc.contributor.authorAkansel, Gur
dc.date.accessioned2025-05-10T19:29:07Z
dc.date.issued2016
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description24th Signal Processing and Communication Application Conference (SIU) -- MAY 16-19, 2016 -- Zonguldak, TURKEY
dc.description.abstractAccurate diagnosis of issues using medical images is crucial. One common approach for decreasing the risk of human diagnosis error is the double reading which is based on the assessment of each medical image by more than one radiologist. A novel method which increases the accuracy of the double reading approach while decreasing the required number of expert radiologist is proposed. The core idea behind the method is the better selection of the second expert by using subjective difficulty level of the medical image for the first doctor. The method estimates the subjective difficulty level by using eye-gaze metrics and the method assigns difficult images to the more experienced radiologists. The expertise level of the doctors are determined by the number of their previous decisions which are matched with the other experts' decisions. Effectiveness of the proposed system is shown by using real chest x-ray images and eye-gaze recordings.
dc.description.sponsorshipIEEE,Bulent Ecevit Univ, Dept Elect & Elect Engn,Bulent Ecevit Univ, Dept Biomed Engn,Bulent Ecevit Univ, Dept Comp Engn
dc.identifier.endpage1212
dc.identifier.isbn978-1-5090-1679-2
dc.identifier.scopusqualityN/A
dc.identifier.startpage1209
dc.identifier.urihttps://hdl.handle.net/20.500.14730/7596
dc.identifier.wosWOS:000391250900279
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isotr
dc.publisherIeee
dc.relation.ispartof2016 24th Signal Processing and Communication Application Conference (Siu)
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectRadiology
dc.subjectCrowd-sourcing
dc.subjectEye-gaze
dc.subjectDouble reading
dc.subjectWorkload Assignment
dc.subjectChest X-ray
dc.titleImproving Accuracy of Double Reading in Chest X-Ray Images by Using Eye-gaze Metrics
dc.typeConference Object

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
7596.pdf
Boyut:
246.28 KB
Biçim:
Adobe Portable Document Format