Comparison of shaping ability of ProTaper Next and 2Shape nickel-titanium files in simulated severe curved canals

dc.authorid0000-0003-3299-3361
dc.authorid0000-0003-3407-9768
dc.authorid0000-0003-3426-2394
dc.authorid0000-0001-6358-6406
dc.contributor.authorStaffoli, Simone
dc.contributor.authorOzyurek, Taha
dc.contributor.authorHadad, Avi
dc.contributor.authorLvovsky, Alex
dc.contributor.authorSolomonov, Michael
dc.contributor.authorAzizi, Hadas
dc.contributor.authorBen Itzhak, Joe
dc.date.accessioned2025-05-10T19:49:33Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractAim: To evaluate the centering ability of ProTaper Next (PTN) and 2Shape (TS) nickel-titanium (NiTi) instruments in terms of maintaining the original root canal configuration in a simulated tooth with severe curvature. Methodology: Twenty standardized simulated curved root canals were prepared to an apical size of 0.25 mm using PTN and TS (n = 10 canal/group) nickel-titanium files. A gig was constructed to enable reproducible image acquisition using a photographic camera. Pre- and post-instrumented images were recorded and superimposed using a computer software. The ability of the instruments to remain centered in the canal was determined by calculating a centering ratio at three independent points of the simulated canal: coronal, middle and apical third of the curvature, (ANOVA) followed by independent sample t-test at 5% significance level. Results: No significant difference was found between the two systems (p > 0.05). At the apical third, the mean centering ratio was significantly higher than the centering ratio of the coronal and the middle thirds in both TS and PTN (p < 0.05). Conclusions: There were no significant differences in the centering ability of the ProTaper Next and 2Shape systems in simulated severe curved canals. Both systems exhibited some degree of transportation, especially in the apical third. (C) 2018 Society Italiana di Endodonzia. Production and hosting by Elsevier B.V.
dc.identifier.doi10.1016/j.gien.2018.05.002
dc.identifier.endpage56
dc.identifier.issn1971-1425
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85055136455
dc.identifier.scopusqualityQ4
dc.identifier.startpage52
dc.identifier.urihttps://doi.org/10.1016/j.gien.2018.05.002
dc.identifier.urihttps://hdl.handle.net/20.500.14730/12074
dc.identifier.volume32
dc.identifier.wosWOS:000447869000002
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Bv
dc.relation.ispartofGiornale Italiano Di Endodonzia
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectCentering ability
dc.subjectCentering ratio
dc.subjectHeat treatment
dc.subject2Shape
dc.subjectProTaper Next
dc.titleComparison of shaping ability of ProTaper Next and 2Shape nickel-titanium files in simulated severe curved canals
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
12074.pdf
Boyut:
462.75 KB
Biçim:
Adobe Portable Document Format