A New Perspective in Comparing Injuries Caused by Short-Duration External and Internal Forces in Saphenous Vein

dc.authorid0000-0002-0845-8898
dc.authorid0000-0003-3953-7131
dc.authorid0000-0002-9491-8220
dc.authorid0000-0002-2395-0004
dc.contributor.authorYalvac, Emine Seyma Denli
dc.contributor.authorCumbul, Alev
dc.contributor.authorUslu, Unal
dc.contributor.authorSoztutar, Erdem
dc.contributor.authorBilisli, Edibe
dc.contributor.authorBalak, Naci
dc.date.accessioned2025-05-10T19:35:05Z
dc.date.issued2019
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractBackground: Great saphenous vein (GSV) graft failure is one of the major reasons for repeat bypass grafting. A comparison of the effects of simultaneous, short-duration, externally squeezing and internally distending forces on the same segment of ex-vivo human GSV has not yet been published, although similar studies have compared the experimental injury of different ex-vivo human veins. Methods: Approximately 8-cm-long segments of GSV were harvested from each of the 15 patients. For each specimen, one end of the vein piece was occluded at a distance of 1 cm with an external cross-clamp for 5 min and the other end was similarly occluded at a distance of 1 cm by an endoluminal balloon. The middle sections of the veins, which were not occluded by any means, were taken as the control group. Two histologists, who were blinded to the groups, graded the hematoxylin and eosin (H&E) and Weigert-Van Gieson (WVG) stained sections semi-quantitatively and performed the histomorphometric measurements. Results: The result of the histopathological evaluation of the intima layer showed that the microscopic scoring of lesions in the balloon group was significantly higher than that in the clamp and control groups (5.16 +/- 1.32, 3.83 +/- 0.75, and 1.00 +/- 1.09, respectively; P < .001). In the adventitia layer, this level of scoring increased more in the clamp group than in the balloon and control groups (5.16 +/- 1.16, 3.00 +/- 0.89, and 0.16 +/- 0.40, respectively; P < .001). Conclusion: Both the endoluminal balloon and external clamp techniques have harmful effects on the vein wall. Studying different kind of forces on different veins cannot provide us with reliable comparisons.
dc.identifier.doi10.1532/hsf.2303
dc.identifier.endpageE69
dc.identifier.issn1098-3511
dc.identifier.issn1522-6662
dc.identifier.issue2
dc.identifier.pmid31013213
dc.identifier.scopus2-s2.0-85065342267
dc.identifier.scopusqualityQ3
dc.identifier.startpageE63
dc.identifier.urihttps://doi.org/10.1532/hsf.2303
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8751
dc.identifier.volume22
dc.identifier.wosWOS:000461831600001
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherForum Multimedia Publishing, Llc
dc.relation.ispartofHeart Surgery Forum
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectEndothelial-Cell Injury
dc.subjectBypass-Surgery
dc.subjectGraft Failure
dc.subjectPressure
dc.subjectConduit
dc.subjectTissue
dc.titleA New Perspective in Comparing Injuries Caused by Short-Duration External and Internal Forces in Saphenous Vein
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8751.pdf
Boyut:
1.39 MB
Biçim:
Adobe Portable Document Format