Coated Copper Wire Calcium Selective Microelectrode for Applications in Dental Medicine

dc.authorid0000-0003-2341-9245
dc.authorid0000-0001-6635-6091
dc.authorid0000-0001-7040-5060
dc.authorid0000-0001-9584-676X
dc.authorid0000-0002-2793-3500
dc.authorid0000-0001-9654-1386
dc.authorid0000-0003-3539-7805
dc.contributor.authorTotu, Eugenia Eftimie
dc.contributor.authorIsildak, Ibrahim
dc.contributor.authorTavukcuoglu, Ozlem
dc.contributor.authorAgir, Ismail
dc.contributor.authorYildirim, Ridvan
dc.contributor.authorNigde, Mustafa
dc.contributor.authorNechifor, Aurelia Cristina
dc.date.accessioned2025-05-10T19:28:25Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractA coated wire calcium selective microelectrode for biological use was developed, comprising a PVC selective matrix containing calcium ionophore IV coated on copper wire, previously covered with a solid-state contact mixture. The obtained calcium microsensor presented a Nernstian answer in a concentration range of 10(-1) to 10(6) mol/L. The selectivity coefficients over the main interfering ions of biological interest proved that the calcium microelectrode is highly selective. Also, the response time (6s) and repeatability have been determined. The pH variation did not significantly modify the calcium microelectrode answer, being stable over the pH range (6.7-7.3) of interest. The obtained calcium microelectrode is simple, inexpensive and able to give reliable electrochemical response, recommending itself as a solution for assessing the level of inorganic ions of the gingival crevicular fluid and saliva. fluid
dc.description.sponsorshipRomanian National Authority for Scientific Research and Innovation, CCCDI - UEFISCDI within PNCDI III [39/2018]; Scientific and Technological Research Council of Turkey (TUBITAK) [BIYOTEG-9170032]; Romanian National Authority for Scientific Research and Innovation, CCDI-UEFISCDI within PNCDI III [30/2016]
dc.description.sponsorshipThis work was supported by a grant of the Romanian National Authority for Scientific Research and Innovation, CCCDI - UEFISCDI, project number 39/2018 COFUND-MANUNET III-HAMELDENT, within PNCDI III and by the Scientific and Technological Research Council of Turkey (TUBITAK), Grant no: BIYOTEG-9170032. Also, the authors acknowledge the support of the grant of the Romanian National Authority for Scientific Research and Innovation, CCDI-UEFISCDI, project number 30/2016, MANUNET II - PRIDENTPRO within PNCDI III.
dc.identifier.endpage4117
dc.identifier.issn0034-7752
dc.identifier.issue11
dc.identifier.scopus2-s2.0-85066761801
dc.identifier.scopusqualityN/A
dc.identifier.startpage4113
dc.identifier.urihttps://hdl.handle.net/20.500.14730/7330
dc.identifier.volume69
dc.identifier.wosWOS:000451931500054
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherRevista Chimie Srl
dc.relation.ispartofRevista De Chimie
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectcalcium microsensor
dc.subjectcoated wire microsensor
dc.subjectsolid-state contact mixture
dc.subjectPVC selective mixture
dc.subjectgingival crevicular fluid
dc.titleCoated Copper Wire Calcium Selective Microelectrode for Applications in Dental Medicine
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
7330
Boyut:
153.31 KB
Biçim:
Adobe Portable Document Format