Coated Copper Wire Calcium Selective Microelectrode for Applications in Dental Medicine
| dc.authorid | 0000-0003-2341-9245 | |
| dc.authorid | 0000-0001-6635-6091 | |
| dc.authorid | 0000-0001-7040-5060 | |
| dc.authorid | 0000-0001-9584-676X | |
| dc.authorid | 0000-0002-2793-3500 | |
| dc.authorid | 0000-0001-9654-1386 | |
| dc.authorid | 0000-0003-3539-7805 | |
| dc.contributor.author | Totu, Eugenia Eftimie | |
| dc.contributor.author | Isildak, Ibrahim | |
| dc.contributor.author | Tavukcuoglu, Ozlem | |
| dc.contributor.author | Agir, Ismail | |
| dc.contributor.author | Yildirim, Ridvan | |
| dc.contributor.author | Nigde, Mustafa | |
| dc.contributor.author | Nechifor, Aurelia Cristina | |
| dc.date.accessioned | 2025-05-10T19:28:25Z | |
| dc.date.issued | 2018 | |
| dc.department | İstanbul Medeniyet Üniversitesi | |
| dc.description.abstract | A coated wire calcium selective microelectrode for biological use was developed, comprising a PVC selective matrix containing calcium ionophore IV coated on copper wire, previously covered with a solid-state contact mixture. The obtained calcium microsensor presented a Nernstian answer in a concentration range of 10(-1) to 10(6) mol/L. The selectivity coefficients over the main interfering ions of biological interest proved that the calcium microelectrode is highly selective. Also, the response time (6s) and repeatability have been determined. The pH variation did not significantly modify the calcium microelectrode answer, being stable over the pH range (6.7-7.3) of interest. The obtained calcium microelectrode is simple, inexpensive and able to give reliable electrochemical response, recommending itself as a solution for assessing the level of inorganic ions of the gingival crevicular fluid and saliva. fluid | |
| dc.description.sponsorship | Romanian National Authority for Scientific Research and Innovation, CCCDI - UEFISCDI within PNCDI III [39/2018]; Scientific and Technological Research Council of Turkey (TUBITAK) [BIYOTEG-9170032]; Romanian National Authority for Scientific Research and Innovation, CCDI-UEFISCDI within PNCDI III [30/2016] | |
| dc.description.sponsorship | This work was supported by a grant of the Romanian National Authority for Scientific Research and Innovation, CCCDI - UEFISCDI, project number 39/2018 COFUND-MANUNET III-HAMELDENT, within PNCDI III and by the Scientific and Technological Research Council of Turkey (TUBITAK), Grant no: BIYOTEG-9170032. Also, the authors acknowledge the support of the grant of the Romanian National Authority for Scientific Research and Innovation, CCDI-UEFISCDI, project number 30/2016, MANUNET II - PRIDENTPRO within PNCDI III. | |
| dc.identifier.endpage | 4117 | |
| dc.identifier.issn | 0034-7752 | |
| dc.identifier.issue | 11 | |
| dc.identifier.scopus | 2-s2.0-85066761801 | |
| dc.identifier.scopusquality | N/A | |
| dc.identifier.startpage | 4113 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14730/7330 | |
| dc.identifier.volume | 69 | |
| dc.identifier.wos | WOS:000451931500054 | |
| dc.identifier.wosquality | N/A | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Revista Chimie Srl | |
| dc.relation.ispartof | Revista De Chimie | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.snmz | KA_WOS_20250302 | |
| dc.subject | calcium microsensor | |
| dc.subject | coated wire microsensor | |
| dc.subject | solid-state contact mixture | |
| dc.subject | PVC selective mixture | |
| dc.subject | gingival crevicular fluid | |
| dc.title | Coated Copper Wire Calcium Selective Microelectrode for Applications in Dental Medicine | |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1










