Shear Wave and Strain Elastographic Features of the Brachial Plexus in Healthy Adults: Reliability of the Findingsa Pilot Study

dc.authorid0000-0003-1433-6149
dc.authorid0000-0001-6247-1738
dc.contributor.authorAslan, Ahmet
dc.contributor.authorAktan, Ahmet
dc.contributor.authorAslan, Mine
dc.contributor.authorGuelseren, Yildiz
dc.contributor.authorKabaalioglu, Adnan
dc.date.accessioned2025-05-10T19:53:48Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractObjectives To determine the sonoelastographic findings for the normal brachial plexus via shear wave elastography (SWE) and strain elastography (SE) and the reliability of the measurements. Methods Thirty-nine healthy adult volunteers were included in the study. The brachial plexus was evaluated with SWE and SE at the interscalene region by 2 observers separately, and the observers were unaware of each other's outcomes. The elastic modulus (kilopascals), shear wave velocity (SWV, meters per second), and strain ratio were obtained. Elasticity patterns on SE were assessed as hard, intermediate, and soft. An intraclass correlation coefficient analysis was performed for determining the reliability of sonoelastographic findings. The correlation of sonoelastographic features with age and sex was investigated. Results The volunteers included 13 men and 26 women. The mean age of the participantsSD was 36.2 +/- 7.8 (range, 25-56) years. The mean elasticity modulus values of the brachial plexus for observers 1 and 2 were 17.03 (95% confidence interval [CI], 15.03, 19.03) and 13.83 (95% CI, 12.23, 15.43) kPa, respectively; the SWVs were 2.24 (95% CI, 2.12, 2.36) and 2.04 (95% CI, 1.93, 2.15) m/s; and the strain ratios were 1.20 (95% CI, 1.18, 1.25) 1.38 (95% CI, 1.22, 1.54). The elasticity pattern was mostly intermediate stiffness for both observers (n=72 [92.3%]; n=75 [96.1%]). The intraclass correlation coefficient was poor to moderate and statistically significant for the elastic modulus, SWV, and elasticity pattern (P<.05 for all parameters). The sonoelastographic characteristics of the brachial plexus had no correlation with age or sex. Conclusions The reliability and reproducibility of sonoelastography of the brachial plexus are low, and the appropriateness of this technique in this manner is controversial.
dc.identifier.doi10.1002/jum.14584
dc.identifier.endpage2362
dc.identifier.issn0278-4297
dc.identifier.issn1550-9613
dc.identifier.issue10
dc.identifier.pmid29480537
dc.identifier.scopusqualityQ2
dc.identifier.startpage2353
dc.identifier.urihttps://doi.org/10.1002/jum.14584
dc.identifier.urihttps://hdl.handle.net/20.500.14730/12847
dc.identifier.volume37
dc.identifier.wosWOS:000446327900006
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWiley
dc.relation.ispartofJournal of Ultrasound in Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectbrachial plexus
dc.subjectelastography
dc.subjecthead and neck
dc.subjectmusculoskeletal (diagnostic)
dc.subjectneurosonology (adult)
dc.subjectperipheral nerve
dc.subjectradiology
dc.subjectshear wave elastography
dc.subjectstrain elastography
dc.titleShear Wave and Strain Elastographic Features of the Brachial Plexus in Healthy Adults: Reliability of the Findingsa Pilot Study
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
12847
Boyut:
516.77 KB
Biçim:
Adobe Portable Document Format