Evaluation of Corneal Topography and Biomechanical Parameters after Use of Systemic Isotretinoin in Acne Vulgaris

dc.authorid0000-0001-5435-075X
dc.authorid0000-0001-8197-2458
dc.authorid0000-0002-4161-0919
dc.contributor.authorYildirim, Yusuf
dc.contributor.authorOlcucu, Onur
dc.contributor.authorAğca, Alper
dc.contributor.authorAlagoz, Cengiz
dc.contributor.authorDemircan, Ali
dc.contributor.authorBasci, Abdurrahman
dc.contributor.authorDemirok, Ahmet
dc.date.accessioned2025-05-10T19:40:54Z
dc.date.issued2014
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractPurpose. We report the effect of isotretinoin on corneal topography, corneal thickness, and biomechanical parameters in patients with acne vulgaris. Method. Fifty-four eyes of 54 patients who received oral isotretinoin for treatment of acne vulgaris were evaluated. All patients underwent a corneal topographical evaluation with a Scheimpflug camera combined with Placido-disk (Sirius), ultrasonic pachymetry measurements, and corneal biomechanical evaluation with an ocular response analyzer at baseline, in the 1st, 3rd, and 6th months of treatment, and 6 months after isotretinoin discontinuation. Results. The thinnest corneal thickness measured with Sirius differed significantly in the 1st, 3rd, and 6th months compared with the baseline measurement; there was no significant change in ultrasonic central corneal thickness measurements and biomechanical parameters (corneal hysteresis and corneal resistance factor) throughout the study. Average simulated keratometry and surface asymmetry index increased significantly only in the first month of treatment according to the baseline. All changes disappeared 6 months after the end of treatment. Conclusion. Basal tear secretion and corneal morphologic properties were significantly influenced during the systemic isotretinoin treatment and the changes were reversible after discontinuation. No statistical important biomechanical differences were found to be induced by isotretinoin.
dc.identifier.doi10.1155/2014/701361
dc.identifier.issn2090-004X
dc.identifier.issn2090-0058
dc.identifier.pmid25525510
dc.identifier.scopus2-s2.0-84918580476
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1155/2014/701361
dc.identifier.urihttps://hdl.handle.net/20.500.14730/10150
dc.identifier.volume2014
dc.identifier.wosWOS:000346712500001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherHindawi Ltd
dc.relation.ispartofJournal of Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectOcular Surface
dc.subjectThickness
dc.subjectScheimpflug
dc.subjectUltrasound
dc.subjectTherapy
dc.titleEvaluation of Corneal Topography and Biomechanical Parameters after Use of Systemic Isotretinoin in Acne Vulgaris
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10150.pdf
Boyut:
1.2 MB
Biçim:
Adobe Portable Document Format