Effect of reapplication on pull-out bond strength of fibre post to root dentin: An in vitro study

dc.authorid0000-0002-2865-372X
dc.authorid0000-0003-0554-4341
dc.contributor.authorIskefli, Nuray
dc.contributor.authorYegin, Elif
dc.contributor.authorSezgin, Guzide Pelin
dc.contributor.authorKaplan, Sema Sonmez
dc.contributor.authorKaplan, Tuna
dc.date.accessioned2025-05-10T19:43:37Z
dc.date.issued2024
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractPurpose: Post removal may be necessary for many reasons and is inevitable after the re-application of a dental post. The present study investigated the bond strength between root dentin and a re-applied fibre-reinforced composite (FRC) post by a pull-out test. Materials and methods: After root canal treatments of 30 extracted human maxillary canine teeth, post spaces were prepared (10 mm), and FRC posts (Hi-Rem Post; Overfibres, I(center dot)mola, Italy) were luted with self-adhesive resin cement. The samples were than randomly divided into test and control groups (n = 15 in each). The FRC posts were removed in the test group, and new posts were cemented. The pull-out test (1 mm/minute speed) was used to measure the bond strength. Failure types were determined using a stereomicroscope. Mann-Whitney U, chi-square and Fisher-Freeman-Halton exact tests were used for statistical analysis. Results: The bond strength values of the test (119.5 +/- 36.86 N) and control (115.55 +/- 55.44 N) groups did not differ significantly (p >.05). In terms of the percentage of failure types, there was a significant difference only in the test group between the mixed failure type and the other failure types (p <.05). Conclusions: The re-application of FRC post did not seem to affect the bond strength. The distribution of failure types was similar between the control and test groups.
dc.description.sponsorshipBiruni University Scientific Research Project Department in Istanbul, Turkey [Biruni-BAP-Altyapimath;-2018-02-04]
dc.description.sponsorshipThe work was supported by Biruni University Scientific Research Project Department in Istanbul, Turkey (project no: Biruni-BAP-Altyap & imath;-2018-02-04) .
dc.identifier.doi10.1016/j.sdentj.2024.01.011
dc.identifier.endpage578
dc.identifier.issn1013-9052
dc.identifier.issn1658-3558
dc.identifier.issue4
dc.identifier.pmid38690387
dc.identifier.scopus2-s2.0-85184273107
dc.identifier.scopusqualityQ2
dc.identifier.startpage574
dc.identifier.urihttps://doi.org/10.1016/j.sdentj.2024.01.011
dc.identifier.urihttps://hdl.handle.net/20.500.14730/10679
dc.identifier.volume36
dc.identifier.wosWOS:001231110400001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofSaudi Dental Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectBond strength
dc.subjectFibre post
dc.subjectPost removal
dc.subjectPull-out test
dc.subjectRe-applied post
dc.titleEffect of reapplication on pull-out bond strength of fibre post to root dentin: An in vitro study
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10679.pdf
Boyut:
3.98 MB
Biçim:
Adobe Portable Document Format