Effect of reapplication on pull-out bond strength of fibre post to root dentin: An in vitro study
| dc.authorid | 0000-0002-2865-372X | |
| dc.authorid | 0000-0003-0554-4341 | |
| dc.contributor.author | Iskefli, Nuray | |
| dc.contributor.author | Yegin, Elif | |
| dc.contributor.author | Sezgin, Guzide Pelin | |
| dc.contributor.author | Kaplan, Sema Sonmez | |
| dc.contributor.author | Kaplan, Tuna | |
| dc.date.accessioned | 2025-05-10T19:43:37Z | |
| dc.date.issued | 2024 | |
| dc.department | İstanbul Medeniyet Üniversitesi | |
| dc.description.abstract | Purpose: Post removal may be necessary for many reasons and is inevitable after the re-application of a dental post. The present study investigated the bond strength between root dentin and a re-applied fibre-reinforced composite (FRC) post by a pull-out test. Materials and methods: After root canal treatments of 30 extracted human maxillary canine teeth, post spaces were prepared (10 mm), and FRC posts (Hi-Rem Post; Overfibres, I(center dot)mola, Italy) were luted with self-adhesive resin cement. The samples were than randomly divided into test and control groups (n = 15 in each). The FRC posts were removed in the test group, and new posts were cemented. The pull-out test (1 mm/minute speed) was used to measure the bond strength. Failure types were determined using a stereomicroscope. Mann-Whitney U, chi-square and Fisher-Freeman-Halton exact tests were used for statistical analysis. Results: The bond strength values of the test (119.5 +/- 36.86 N) and control (115.55 +/- 55.44 N) groups did not differ significantly (p >.05). In terms of the percentage of failure types, there was a significant difference only in the test group between the mixed failure type and the other failure types (p <.05). Conclusions: The re-application of FRC post did not seem to affect the bond strength. The distribution of failure types was similar between the control and test groups. | |
| dc.description.sponsorship | Biruni University Scientific Research Project Department in Istanbul, Turkey [Biruni-BAP-Altyapimath;-2018-02-04] | |
| dc.description.sponsorship | The work was supported by Biruni University Scientific Research Project Department in Istanbul, Turkey (project no: Biruni-BAP-Altyap & imath;-2018-02-04) . | |
| dc.identifier.doi | 10.1016/j.sdentj.2024.01.011 | |
| dc.identifier.endpage | 578 | |
| dc.identifier.issn | 1013-9052 | |
| dc.identifier.issn | 1658-3558 | |
| dc.identifier.issue | 4 | |
| dc.identifier.pmid | 38690387 | |
| dc.identifier.scopus | 2-s2.0-85184273107 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 574 | |
| dc.identifier.uri | https://doi.org/10.1016/j.sdentj.2024.01.011 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14730/10679 | |
| dc.identifier.volume | 36 | |
| dc.identifier.wos | WOS:001231110400001 | |
| dc.identifier.wosquality | N/A | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.language.iso | en | |
| dc.publisher | Elsevier | |
| dc.relation.ispartof | Saudi Dental Journal | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | KA_WOS_20250302 | |
| dc.subject | Bond strength | |
| dc.subject | Fibre post | |
| dc.subject | Post removal | |
| dc.subject | Pull-out test | |
| dc.subject | Re-applied post | |
| dc.title | Effect of reapplication on pull-out bond strength of fibre post to root dentin: An in vitro study | |
| dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1










