Examination and Comparison of Electrically Evoked Compound Action Potentials and Electrically Evoked Auditory Brainstem Response Results of Children with Cochlear Implantation without Inner Ear Anomaly

dc.authorid0000-0002-9803-9258
dc.contributor.authorBayrak, Seda
dc.contributor.authorMutlu, Basak
dc.contributor.authorKirkim, Gunay
dc.contributor.authorSerbetcioglu, Bulent
dc.date.accessioned2025-05-10T19:59:30Z
dc.date.issued2019
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractObjective: To investigate the relationship between electrically evoked compound action potentials (ECAP) and electrically evoked auditory brainstem responses (EABR) in children with cochlear implants (CI) without inner ear anomalies. Methods: Sixteen children between the ages of two and six years who were CI users participated in the study. ECAP thresholds were recorded from one electrode in the basal, medial, and apical regions of the cochlear implant. EABRs were recorded from electrodes whose ECAP thresholds were determined. The latency- intensity functions, amplitude and morphological analyzes of the eIII and eV waves at 200 and 180 current unit (CU) excitation levels were performed. The data obtained were analyzed statistically. Results: ECAP thresholds were found to be 171.5 +/- 11.38, 169.69 +/- 20.32 and 160.81 +/- 20.03 CU at the basal, medial and apical electrodes, respectively. EABR thresholds were also found to be 169.69 +/- 12.17, 165.62 +/- 16.41 and 160 +/- 15.49 CU in basal, medial and apical electrodes, respectively. There was a strong pos- itive correlation between ECAP and EABR thresholds in apical, medial and basal electrodes (p< 0.05). EABR threshold levels were not significantly different between basal, medial and apical region electrodes (p> 0.05), and ECAP threshold values were significantly different between apical and basal region electrodes (p= 0.002). When the significance values of EABR eV wave latencies were analyzed in terms of electrode region, the difference between basal and apical regions was found to be significant (p=0.03). Conclusion: Consistency was found between ECAP and EABR recordings. However, it was concluded that one could not be preferred over the other because the data quality of the two tests was different. In future studies, ECAP and EABR recordings may be recommended by selecting more electrodes for stimulation.
dc.identifier.doi10.5152/tao.2019.4130
dc.identifier.endpage85
dc.identifier.issn2667-7466
dc.identifier.issn2667-7474
dc.identifier.issue2
dc.identifier.pmid31360925
dc.identifier.scopusqualityN/A
dc.identifier.startpage81
dc.identifier.trdizinid338466
dc.identifier.urihttps://doi.org/10.5152/tao.2019.4130
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/338466
dc.identifier.urihttps://hdl.handle.net/20.500.14730/13875
dc.identifier.volume57
dc.identifier.wosWOS:000475757700005
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakTR-Dizin
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherGalenos Yayincilik
dc.relation.ispartofTurkish Archives of Otorhinolaryngology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectCochlear implant
dc.subjectelectrophysiological studies
dc.subjectelectrically evoked compound action potential
dc.subjectelectrically evoked auditory brainstem response
dc.titleExamination and Comparison of Electrically Evoked Compound Action Potentials and Electrically Evoked Auditory Brainstem Response Results of Children with Cochlear Implantation without Inner Ear Anomaly
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
13875.pdf
Boyut:
151.97 KB
Biçim:
Adobe Portable Document Format