Sonographic fetal weight estimation prior to delivery: analysis of accuracy and interobserver variability between obstetrician and radiologist

dc.authorid0000-0001-5313-9186
dc.contributor.authorAksoy, Huseyin
dc.contributor.authorOzdamar, Ozkan
dc.contributor.authorAksoy, Ulku
dc.contributor.authorCagli, Fulya
dc.contributor.authorKaradağ, Ozge Idem
dc.contributor.authorAcmaz, Gokhan
dc.contributor.authorBabayigit, Mustafa Alparslan
dc.date.accessioned2025-05-10T19:28:55Z
dc.date.issued2016
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractThe aim of this study was to evaluate the interobserver reliability of sonographic fetal weight estimation between experienced obstetrician and radiologist immadiately prior to delivery and to compare the sonographic accuracies of estimated fetal weights (EFW) between the sonographers. This was a prospective study of singleton pregnancies that underwent sonographic fetal weight estimation prior to scheduled delivery. One obstetrician and one radiologist, performed all examinations prior to delivery. Sonographic fetal weight estimations were obtained from each ultrasonographic examination. EFWs were compared with the actual birth weight (ABW) and interobserver reliability of sonographic fetal weight estimation between two sonographers was assessed. A total of 245 subjects were included. Inter-observer reliability coefficient for EFW was 0.864 (95% confidence interval: 0.825-0.894, P < 0.001). Mean values of EFWs by radiologist and obstetrician did not significantly differ (P = 0.480) while both did significantly differ from the ABW (P < 0.001, for both comparisons). The mean absolute error for EFW obtained by radiologist and obsterician was 227 (+/- 160) and 197 (+/- 138), respectively (P < 0.01). The mean absolute percentage error for EFW obtained by radiologist and obsterician was 7.09 (+/- 5.17) and 6.15 (+/- 4.38), respectively (P < 0.01). EFWs measured by radiologists and obstetricians are similar but both are significantly distant from the ABW. However, obstetricians measure EFW significantly more accurate than the radiologists do.
dc.identifier.endpage9556
dc.identifier.issn1940-5901
dc.identifier.issue6
dc.identifier.scopus2-s2.0-84977134528
dc.identifier.scopusqualityN/A
dc.identifier.startpage9550
dc.identifier.urihttps://hdl.handle.net/20.500.14730/7524
dc.identifier.volume9
dc.identifier.wosWOS:000379156000086
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherE-Century Publishing Corp
dc.relation.ispartofInternational Journal of Clinical and Experimental Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.subjectInterobserver reliability
dc.subjectfetal weight estimation
dc.subjectultrasonography
dc.titleSonographic fetal weight estimation prior to delivery: analysis of accuracy and interobserver variability between obstetrician and radiologist
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
7524.pdf
Boyut:
244.96 KB
Biçim:
Adobe Portable Document Format