Electrophysiological and Histopathological Evaluation of Effects of Sodium-2 Mercaptoethanesulfonate Used for Middle Ear Surgery on Facial Nerve Functions

dc.authorid0000-0001-6674-9389
dc.contributor.authorEğilmez, Oğuz Kadir
dc.contributor.authorKökten, Numan
dc.contributor.authorBaran, Mustafa
dc.contributor.authorKalcıoğlu, M. Tayyar
dc.contributor.authorEkici, Isin Dogan
dc.contributor.authorTekin, Muhammet
dc.date.accessioned2025-05-10T19:31:44Z
dc.date.issued2018
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description5th International Specialists Conference on Ear, Nose and Throat Disorders -- NOV 07-08, 2016 -- Alicante, SPAIN
dc.description.abstractOBJECTIVE: Sodium-2-mercaptoethanesulfonate (MESNA) is widely used in medicine because of its antioxidant and mucolytic effects. In recent years, it has been used in otologic surgery. Because it cleaves disulfide bonds, it is used to easily dissect the epithelial matrix in cholesteatoma and atelectasis. In this study, we hypothesized that MESNA does not have any toxic effect on the facial nerve, and the effects of MESNA on the facial nerve were examined histologically and electrophysiologically. MATERIALS and METHODS: Twenty Wistar albino rats were used. Groups A and B were designated as the control and sham groups, respectively. The animals in groups C and D were administered 20% and 50% of MESNA solution, respectively, after the facial nerve was exposed in the parotid region. Electromyography (EMG) measurements were performed preoperatively and postoperatively at 4 weeks. The animals were subsequently euthanized; facial nerve samples were taken for histopathological examination. RESULTS: When EMG parameters were compared within and between each group, preoperative and postoperative results were not statistically significantly different. Histopathological examination showed that MESNA did not cause any inflammation, granulation tissue, or foreign body reaction. CONCLUSION: To the best of our knowledge, the effects of MESNA on facial nerve functions have not been investigated. In this study, the effects of MESNA after direct application to the facial nerve were examined electrophysiologically and histologically, and it was determined that MESNA did not cause any toxic effects. It was concluded that MESNA can, therefore, be safely used during middle ear surgery.
dc.identifier.doi10.5152/iao.2017.3888
dc.identifier.endpage244
dc.identifier.issn1308-7649
dc.identifier.issn2148-3817
dc.identifier.issue2
dc.identifier.pmid29283098
dc.identifier.scopus2-s2.0-85053738033
dc.identifier.scopusqualityQ3
dc.identifier.startpage239
dc.identifier.urihttps://doi.org/10.5152/iao.2017.3888
dc.identifier.urihttps://hdl.handle.net/20.500.14730/8026
dc.identifier.volume14
dc.identifier.wosWOS:000456115400015
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherAves
dc.relation.ispartofJournal of International Advanced Otology
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectMESNA
dc.subjectrat
dc.subjectelectromyography
dc.subjecthistopathology
dc.titleElectrophysiological and Histopathological Evaluation of Effects of Sodium-2 Mercaptoethanesulfonate Used for Middle Ear Surgery on Facial Nerve Functions
dc.typeConference Object

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
8026.pdf
Boyut:
1.62 MB
Biçim:
Adobe Portable Document Format