Energy and exergy analysis of a combined system: cascade organic Rankine cycle and cascade refrigeration cycle

dc.authorid0000-0002-1907-9420
dc.authorid0000-0001-7387-7709
dc.authorid0000-0003-1236-0516
dc.contributor.authorRabah, Touaibi
dc.contributor.authorKöten, Hasan
dc.contributor.authorFadhila, Boudjema
dc.contributor.authorSalma, Selmane
dc.contributor.authorMohamed, Hemis
dc.date.accessioned2025-05-10T19:53:00Z
dc.date.issued2021
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractIn this paper, a new combined system is proposed for recovering thermal energy at medium temperature using a cascade organic Rankine cycle to feed a cascade refrigeration cycle. Energy and exergy analysis is applied to the combined system to determine its performance using different working fluids under the same operating conditions taking into account the effect of some operating parameters and the selection of organic fluids on cycle performance. The pair of organic fluid (Toluene/R245fa) used for the cascade organic Rankine cycle and the pairs (R717/R744, R717/R23, R1344123) used for the cascade refrigeration cycles. The results show that the combined system function with the couple (R717/R23) for cascade refrigeration cyde gives better exergy efficiency 50.03% compared to other couples, 49.57% for the couple (R717/R744), and 48.01% for the couple (R134a/R23). The thermodynamic evaluation shows that the operating temperatures, such as the cascade organic Rankine cycle evaporation temperature and the cascade refrigeration cycle evaporation temperature influence the performance of the combined system.
dc.description.sponsorshipUniversity Djilali Bounaama Khemis Miliana (Algeria)
dc.description.sponsorshipThe authors thank the University Djilali Bounaama Khemis Miliana (Algeria) for funding this study.
dc.identifier.doi10.18186/thermal.977992
dc.identifier.endpage1149
dc.identifier.issn2148-7847
dc.identifier.issue5
dc.identifier.scopus2-s2.0-85113164048
dc.identifier.scopusqualityQ3
dc.identifier.startpage1139
dc.identifier.trdizinid452808
dc.identifier.urihttps://doi.org/10.18186/thermal.977992
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/452808
dc.identifier.urihttps://hdl.handle.net/20.500.14730/12584
dc.identifier.volume7
dc.identifier.wosWOS:000680850200010
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherYildiz Technical Univ
dc.relation.ispartofJournal of Thermal Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250302
dc.subjectOrganic rankine cycle
dc.subjectCascade refrigeration
dc.subjectExergy analysis
dc.titleEnergy and exergy analysis of a combined system: cascade organic Rankine cycle and cascade refrigeration cycle
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
12584.pdf
Boyut:
815.33 KB
Biçim:
Adobe Portable Document Format