Integration of inferior vena cava measurements into routine functional echocardiography in preterm neonates. Are We There Yet?

dc.authorid0000-0001-8023-8075
dc.contributor.authorUnal, Irem
dc.contributor.authorImamoglu, Ebru Yalin
dc.contributor.authorOzumut, Sibel Hatice
dc.contributor.authorOvali, Fahri
dc.date.accessioned2025-11-16T19:33:52Z
dc.date.issued2025
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractObjective To evaluate baseline inferior vena cava measurements and investigate the clinical factors that may affect inferior vena cava diameters and hemodynamic changes during the first week of life in preterm neonates. Study Design This prospective observational study included a consecutive cohort of 30 preterm neonates born at < 34 weeks gestation. Echocardiographic parameters and inferior vena cava diameters were measured on postnatal 1st, 3rd, and 7th days, and inferior vena cava indices were calculated. Results Significant changes in inferior vena cava parameters were observed during the first postnatal week. The median inferior vena cava maximum diameter increased from 2.77 [2.36-3.33] mm on the 1st day to 3.09 [2.59-3.47] mm on the 3rd day, then decreased to 2.63 [2.32-3.27] mm on the 7th day (p: 0.048). The median inferior vena cava indices, including collapsibility, distensibility, and respiratory variation indices, were 22.24%, 28.61%, and 25.02% on the 1st day, respectively. These indices peaked on day 3 (26.20%, 35.51%, and 30.15%, respectively) before decreasing by day 7 (21.45%, 27.33%, and 24.03%, respectively) (p: 0.034 for all indices). Conclusion This study reported baseline inferior vena cava parameters in preterm neonates during the first week of life. These inferior vena cava parameters might be integrated into routine hemodynamic assessment to determine preload and intravascular volume status. Further studies with larger samples are needed to assess inferior vena cava parameters in preterm neonates more accurately and reliably.
dc.identifier.doi10.1038/s41372-025-02271-8
dc.identifier.endpage919
dc.identifier.issn0743-8346
dc.identifier.issn1476-5543
dc.identifier.issue7
dc.identifier.pmid40155453
dc.identifier.scopus2-s2.0-105001477677
dc.identifier.scopusqualityQ1
dc.identifier.startpage914
dc.identifier.urihttps://doi.org/10.1038/s41372-025-02271-8
dc.identifier.urihttps://hdl.handle.net/20.500.14730/15174
dc.identifier.volume45
dc.identifier.wosWOS:001455718100001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringernature
dc.relation.ispartofJournal of Perinatology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250302
dc.titleIntegration of inferior vena cava measurements into routine functional echocardiography in preterm neonates. Are We There Yet?
dc.typeArticle

Dosyalar