Strain and shearwave sonoelastographic findings of quadriceps tendon in patients with chronic kidney disease. Are they reliable?

dc.contributor.authorGülseren, Yıldız
dc.contributor.authorAslan, Ahmet
dc.contributor.authorBuz, Ayşenur
dc.date.accessioned2025-05-10T15:23:59Z
dc.date.issued2022
dc.departmentİstanbul Medeniyet Üniversitesi
dc.description.abstractAim: In this study, we aimed to compare the strain (SE) and shear wave elastography (SWE) findings of the quadriceps tendons (QT) of the patients with chronic kidney disease (CKD) and healthy volunteers (HV), and estimate the reliability of the evaluations. Materials and Methods: Twenty-nine HV and twenty-seven patients with CKD were enrolled. All sonoelastographic examinations were performed separately by two observers. The QT thickness (QTT), SWE, and SE findings including the tissue elastic modulus (EM), shear wave velocity (SWV), and the elasticity patterns were obtained and compared. Interobserver agreement was evaluated to test the reliability of the findings. Results: The QT in CKD patients is thinner than HV (p = 0.001 for both observers). The elasticity patterns of QT were mostly intermediate stiffness for both observers (p < 0.05 for both observers). The mean EM values in the patient group were significantly higher than HV for both observers (p < 0.05 for both observers). The mean SWVs were significantly higher in the patient group (p < 0.05 for both observers). SWV showed weak, significant, and negative correlations with the hemodialysis (HD) duration (p < 0.05 for both observers). The interobserver agreements were moderate to excellent for QTT, EM, SWS, and SE patterns (p < 0.01 for all parameters). Conclusion: QTT and its elasticity are decreased in patients with CKD. The QTT and SE patterns may be the choice to determine the elasticity in CKD patients with good reliability values rather than SWE. But, there is still debate on the reliability of sonoelastographic findings, to ensure standardization of the factors affecting reliability, they should be well understood. © 2022 Wiley Periodicals LLC.
dc.description.sponsorshipEuropean Federation of Societies for Ultrasound in Medicine and Biology; Toshiba Turkey Medical Systems
dc.identifier.doi10.1002/jcu.23199
dc.identifier.endpage555
dc.identifier.issn0091-2751
dc.identifier.issue4
dc.identifier.pmid35315946
dc.identifier.scopus2-s2.0-85127112352
dc.identifier.scopusqualityQ3
dc.identifier.startpage549
dc.identifier.urihttps://doi.org/10.1002/jcu.23199
dc.identifier.urihttps://hdl.handle.net/20.500.14730/6574
dc.identifier.volume50
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofJournal of Clinical Ultrasound
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_Scopus_20250302
dc.subjectquadriceps tendon; reliability; shear wave elastography; sonoelastography; strain elastography
dc.titleStrain and shearwave sonoelastographic findings of quadriceps tendon in patients with chronic kidney disease. Are they reliable?
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
6574
Boyut:
2.16 MB
Biçim:
Adobe Portable Document Format